Software
English, Revision 02, Date: 12.07.2011
37
5.2.2.1
Main Menu
Figure 14
Main menu of the monitor program
Each of the screen menus contains important system variables in the first line (refer
also to Table 36), as they also appear in the output telegram (described in section
4.3.2.1.1 on page 18). The last line on the screen contains possible status messages,
if e.g. predetermined value ranges have not been observed during input.
Description of the system variables
S
Measured voltage of the sum coil within the cover of the casing
in samples (max. 1023).
D
Measured voltage of the difference coil within the cover of the
casing in samples (max. ±1023).
Code
The 32 information bits of the transpondercode in hexadecimal
notation.
Read
Number of readings per transponder crossing. This value is pre-
served until another transponder is detected. It is also deleted
through Noise.
E
State of system in hexadecimal notation. The meaning of each
bit is explained in Table 7 on page 19.
N
Number of reading errors per transponder crossing. This value is
stored until a new transponder has been detected.
Table 36
Description of the system variables (monitor program)
S:0022 D:+0025 Code: 000fffff Read: 114 E: 0120 N: 0 Ftx[Hz]:128000
(W)rite Transponder
(S)erial Output
P(a)rallel Interface
(C)AN-Parameters
P(o)sitioning Pulse
D(e)coding
CS(V) 38,4KB:Code,Sum,Dif,Tr,Co,Po,Rd,Cnt<crlf>
S(y)stemstatus
(P)assword
(L)oad Values to EEProm
Se(r)vice
Se(t)up Ref.transponder Values <S:969 D:-560>
(U)pdate Firmware
(Q)uit Monitor
Software Version 71914A71.08 / 15.APR.2009 Serial Number: 9999999