ECOLOGIC 30 | instructions for use, maintenance and installation |
June 2015
26
Button
–
Press during operation to
decrease desired water temperature in the boiler for a degree.
9.1.
BOILER DURING OPERATION
The display shows current operation phase (e.g. TestFire, HeatUp etc.). Upper display shows set and
actual boiler power alternately every 5 seconds.
Press
to increase set power value, and press
button –
to decrease it.
Press
MENU button
to display set water temperature in the boiler. You can modify it with
b
and -
.
The boiler operates at set power, until water temperature in the boiler reaches modulation threshold
or until smoke gases reach limits. In first case, Regu H20 is displayed, and in second Regu Gas.
In case of power outage for less than 2 minutes, the boiler resumes normal operation when power
supply restores. If the outage lasts more than 2 minutes, the boiler automatically performs safety
shutdown and cooling and then restarts.
9.2.
BOILER SHUTDOWN
When pressing and holding the
ON/OFF button
for more than half a second (during boiler operation),
the display shows
ON
, and the boiler starts shutdown sequence once the button is released. Dosing
screw turns off and the display indicates
STOP FIRE
. Fans operate at high speed to prevent excessive
increase of water temperature in the boiler. When the boiler cools down under set temperature, fans
switch to maximum speed and blow out the last parts from the firebox. Display indicates
OFF.
9.3.
BOILER ACTIVATION
When pressing and holding the
ON/OFF button
for more than half a second (boiler at standstill), the
display shows
OFF
, and the boiler begins activation sequence once the button is release. Display
indicates
TESTFIRE
. Fans operate at high speed to clean the firebox. Dosing screw is at standstill,
spark plug is heating.
If the firebox temperature is low, sequence
HEAT UP
begins, where pellets are dosed quickly and fans
stand still. Then sequences
Fuel IGNI
and
TEST IGNI
start, until the boiler reaches conditions for
transition to burning phase (
BURN
).
Содержание Aqua ECOLOGIC
Страница 32: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 32 Figure 12...
Страница 41: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 41 service...
Страница 42: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 42 service...
Страница 43: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 43 service...
Страница 44: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 44 service...
Страница 45: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 45 service...
Страница 46: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 46 service service...
Страница 52: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 52...
Страница 53: ...__________ PELLET BOILER ECOLOGIC 30 Instructions for use maintenance and installation June 2015...