AQUA ECOLOGIC | instructions for use, maintenance and installation |
September 2015
11
Figure 1 Figure 2
When using the connecting pipe between the stove and the flue drain pin, be sure to use a "T" connector
(as shown in Figures 5 and 6), with the clean-out cover (cap) next to the stove. Applying the "T" connector
must enable the collection of ash, which is produced inside the tube, and the smoke drain pipe must
occasionally be cleaned without having to remove the tube. The smoke is under mild pressure and therefore
it is required to check the cover (cap) for cleaning the exhaust gas system that is perfectly sealed and it
remains so after each cleaning. Make sure to perform the same sequence for assembly and check the
condition of the seals.
Install the flue pipes pursuant to Figure 7.
It is strictly recommended to avoid the use of horizontal extensions, and if necessary, make sure that the
pipe is not bent but that it has the slope of at least 5%. The horizontal part of the drain flue pipes must not
in any case exceed the length of 3 m.
It is not recommended to connect the smoke exhaust directly to the stove with a horizontal part longer than
1 m. See Figures 4,5,6 and 8. After the T branch it is necessary
to set up a vertical extension of Ø 80mm
in length for at least 1-
1.5 m, and only after that to move to the horizontal extension of Ø 80mm and a
vertical extension of Ø 80 or Ø 100mm, depending on the height of the flue pipe (chimney) as shown in
Table 1.
When connecting the stove to the chimney using fittings, one must install a knee with a hole for cleaning
(Figure 2a). Using the knee with an opening for cleaning allows for regular cleaning, without the need to
dismantle the pipes. Drain gases in the chimney connector are under mild pressure so it is necessary to
check that the cover for cleaning the ashes is completely sealed and to seal it after each cleaning. Please
make sure everything is properly returned to its place, and check the condition of the seals.
Содержание Aqua ECOLOGIC
Страница 32: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 32 Figure 12...
Страница 41: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 41 service...
Страница 42: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 42 service...
Страница 43: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 43 service...
Страница 44: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 44 service...
Страница 45: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 45 service...
Страница 46: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 46 service service...
Страница 52: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 52...
Страница 53: ...__________ PELLET BOILER ECOLOGIC 30 Instructions for use maintenance and installation June 2015...