AQUA ECOLOGIC | instructions for use, maintenance and installation |
September 2015
48
- ELECTRIC SAFETY
The stove is protected from high current disturbances using standard fuses that are located in the main
switch on the back side of the stove and on the control panel - the motherboard.
- FLUE GASES FAN
If the fan stops, the motherboard immediately blocks the supply of pellets and an alarm signal will show.
- GEAR MOTOR
When the gear motor stops working, the stove keeps on working until the flame, due to the lack of oxygen,
goes out and until the stove reaches the minimal cooling level.
- INTERRUPTION OF ELECTRICITY
If there is a short interruption of electricity the stove automatically starts to cool down.
- NO IGNITION
If there is no flame when you turn the stove on the stove goes into an alarming state.
18. FAILURES - CAUSES
– SOLUTIONS
PROBLEMS
POSSIBLE CAUSES
SOLUTIONS
Wooden granules
are not put into the
firebox,
in
the
combustion
chamber.
1. The wooden granules tank is
empty.
2. The infinity spiral is blocked.
3. The gear motor of the infinity
spiral is defective.
4. Electronic card is defective.
1. Fill the tank
2. Empty the tank and unblock the spiral -
snail
3.
Change the gear motor
4.
Change the electronic card
The flame is out or
the stove turns off
automatically.
1. The wooden granules tank is
empty.
2. The combustion chamber is not
supplied
with
the
wooden
granules.
3. Safety probe intervention for the
wooden granules temperature.
1. Fill the tank with wooden granules.
2. See last instruction.
3. Let the stove cool off completely and turn
in back on again. If the problem persists call
technical support.
4.Close the door or change the glass sealing
with original sealing.
Содержание Aqua ECOLOGIC
Страница 32: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 32 Figure 12...
Страница 41: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 41 service...
Страница 42: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 42 service...
Страница 43: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 43 service...
Страница 44: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 44 service...
Страница 45: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 45 service...
Страница 46: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 46 service service...
Страница 52: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 52...
Страница 53: ...__________ PELLET BOILER ECOLOGIC 30 Instructions for use maintenance and installation June 2015...