AQUA ECOLOGIC | instructions for use, maintenance and installation |
September 2015
33
16.2.
WHEN THE BOILER IS ON
The display shows the current phase of the mode of operation (for example TestFire, HeatUp, etc.) and
alternately on the upper display shows every 5 seconds the set and the actual capacity of the boiler.
By pressing the
+
button
you will increase the power of the stove, while by pressing the
- button
you will
decrease it.
By pressing the
MENU button
again you activate the flashing of the set parameter values, which can be
adjusted by pressing the
+ and - buttons
.
The stove works with the preset power until the room temperature reaches the modulation threshold or until
flue gases reach their limit values. In the first case the regulation of H2O is shown, while in the second case
the Gas regulation is shown.
In the event of a short power interruption (up to 2 minutes) after the power is restored, the stove continues
to operate in a manner as before the power failure. If the interruption is prolonged, the stove automatically
executes the safety shut-off and cooling so you should turn it back on.
16.3.
TURNING THE BOILER OFF
Pressing the
ON/OFF button
for longer than about half a second while the stove is running the display
shows
ON
and
OFF
.
Once the button is released, the stove begins the process of turning off. The screw
conveyor stops,
STOP FIRE
shows on the display, fans operate at maximum speed to clean the firebox.
Once the combustion chamber is cooled down to the appropriate temperature, the stove shuts down and
goes into sleep mode. The display will read
OFF
.
TURNING THE BOILER ON
Pressing the
ON/OFF button
for longer than about half a second while the stove is not running the display
shows
ON
and
OFF
.
Once the button is released, the stove begins the process of turning on. The display
reads
TESTFIRE
, fans are working at full speed to clean the combustion chamber, screw conveyor is not
moving, the lighter is heated. After that, if the temperature of the stove is low, it will start the process of
HEATING UP
in which the pellets are quickly dispensed and the fans rest. After that the procedures
Fuel
IGNI
and
TEST IGNI
are started while the boiler reaches the conditions for transition to the (
BURN
) burning
phase.
Pressing the MENU button for 2 seconds (after you let go of the button tH20 is displayed) the
current room temperature is displayed.
Press the + or - to choose other temperature and fan
display status.
ATTENTION
Содержание Aqua ECOLOGIC
Страница 32: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 32 Figure 12...
Страница 41: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 41 service...
Страница 42: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 42 service...
Страница 43: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 43 service...
Страница 44: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 44 service...
Страница 45: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 45 service...
Страница 46: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 46 service service...
Страница 52: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 52...
Страница 53: ...__________ PELLET BOILER ECOLOGIC 30 Instructions for use maintenance and installation June 2015...