B) Maximum cross section is 15 x 15 cm or a 15-cm diameter, with the maximum height of 4-5 m.
C) Gasket
D) Inspection hole - for control
Flue pipes that are in poor shape, or are made out of inappropriate materials (asbestos cement, galvanized
sheet, etc. with rough or porous surfaces) are inadequate and jeopardize the proper functioning of the
stove.
The smoke can be drained through a classic smoke pipe (see next Figure), provided that it meets the
following requirements:
- Check the maintenance of the drain flue pipes or chimneys. If the smoke drain pipe is old it should be
replaced with a new one. If the chimney is damaged it is good to repair it or rebuild it by inserting a steel
pipe that is properly insulated with mineral wool.
- The smoke can be discharged directly into the smoke pipe (chimney) only if it has a cross-section of up
to 15 x 15 cm, or a diameter of up to 15 cm, and if there is a cover for checking and cleaning.
-
If the chimney has a larger cross section
than 15x15cm, or a diameter greater than 15cm, a possible
increased regulation of draft (its decrease) in the chimney can be made in three ways:
1. If in the bottom of the chimney there is an opening for cleaning it should be partially open.
2. Insert a steel pipe in the chimney with a diameter of 10cm, if there is a possibility for such reparation of
the chimney.
3. By adjusting certain parameters in the stove. This adjustment must be done only by an authorized service
of GORENJE.
- Make sure that the connection to home chimney is properly sealed.
- Avoid contact with material that burns easily (such as wooden beams), and in all cases they should be
isolated with anti-fire material (see Figure 2).
A) Mineral wool
B) Steel pipes
C) A baffle plate.
The stove is designed to be connected to the chimney flue pipes with a diameter of 80mm. If you are not
using a standard chimney, but you have a new chimney, or you are modifying the existing one, use insulated
stainless pipes (double wall) with a diameter given in Table 1. Flexible pipes are not permitted.
SYSTEM TYPE
DIAMETER mm
SYSTEM MARK
Pipe length less than 5 m
80
acceptable
Pipe length more than 5 m
100
required
To be installed in places above 1,200 meters above sea level
100
recommended
Table 1
Содержание Aqua ECOLOGIC
Страница 32: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 32 Figure 12...
Страница 41: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 41 service...
Страница 42: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 42 service...
Страница 43: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 43 service...
Страница 44: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 44 service...
Страница 45: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 45 service...
Страница 46: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 46 service service...
Страница 52: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 52...
Страница 53: ...__________ PELLET BOILER ECOLOGIC 30 Instructions for use maintenance and installation June 2015...