The opening of the outer supply of combustion air
must not be connected
by pipes.
If the room has some other devices for heating, the supply of combustion air must ensure the
amount of air that is required for proper operation of the device.
Figure 8: Minimum gaps for setting up ventilation grilles.
For proper and safe placement of ventilation grilles see data given in Table 4. These are the minimum
distances from each airspace or smoke extraction. This value can change the configuration of the air
pressure. It should correspond to the ordering to secure that the open window draws outside air, depriving
the stove of it.
Ventilation grid must be set up at least
1 m
under
doors, windows, gas exhausts, air chambers, etc.
1 m
horizontally from
0.3 m
above
2 m
from
the smoke exhaust
Table 4:
The minimum distance for the supply of combustion air
4.5 CONNECTING THE POWER
These stoves are connected to electricity. Our stoves have electrical cables that are suitable for medium
temperature. If you need to replace the power cord (if it is damaged, for example) then consult with our
authorized technical staff. Before you plug in the electric stove note the following:
- That the characteristics of electrical systems correspond to the information that is specified in the data on
the identification plate on the stove.
- If the smoke extraction system is metal, it must have a grounding terminal in accordance with the existing
standards and legislation.
Grounding is the law.
- The electrical cable must not at any time reach a temperature that is 80
0
C above the ambient temperature.
When the stove is installed and placed in its spot, a bipolar switch or socket must be easily accessible.
Содержание Aqua ECOLOGIC
Страница 32: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 32 Figure 12...
Страница 41: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 41 service...
Страница 42: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 42 service...
Страница 43: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 43 service...
Страница 44: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 44 service...
Страница 45: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 45 service...
Страница 46: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 46 service service...
Страница 52: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 52...
Страница 53: ...__________ PELLET BOILER ECOLOGIC 30 Instructions for use maintenance and installation June 2015...