HEATING COIL
The heating coil in the boiler is constructed of high quality 1/2"
(13mm) ID Sch. 80 steel tubing for long service. Proper care of
the coil will maximize its life. Care should be taken to prevent
objects from falling into the heating coil. Such objects could cause
poor burner performance. In cases where very hard water is used,
mineral scale can build up and restrict the water flow through the
coil. It may be necessary to descale the coil annually. A coil
descaler (part # HPW-DSC) is available from Goodway
Technologies Corp.
PUMP LUBRICATION
These units are equipped with an oil bath pump. When shipped,
the crankcase is filled with the proper amount of oil. Due to the
possibility of spillage in shipment, the oil level should be checked
prior to the first use of the machine, as well as prior to each use.
With the machine resting on a level surface, the correct oil level
should reach the middle of the sight glass on the side of the pump.
If the oil level is low, add sufficient oil to the crankcase.
DO NOT
OVERFILL.
The high-pressure pump crankcase takes Cat Pump Oil or premium
10W30
hydraulic oil
(not motor oil). Cat Pump Oil (HPW-CPO)
is available from Goodway Technologies Corp.
CHANGING PUMP OIL
Pump oil should be changed after the first 50 hours of operation
and then after every 50 -100 hours.