GETTING READY
1. Check all oil level before any operation to ensure good start up
and problem free performance.
2. Connect a clean water hose capable of delivering 2 GPM (7.6
LPM) for the HPW-1000, 2.2 GPM (8.3 LPM) for the HPW-
2000, or 4 GPM (15.1 LPM) for the HPW-2000-3 to the garden
hose fitting located on the pump inlet. Make sure the screen
washer is clean and in place. Consult the Goodway catalog for
heavy-duty water supply hose (part # WSH-R50).
NOTE:
Any restriction in the water supply may cause
cavitation and pump damage. Positive inlet pressure above 25
PSI (1.7 BAR) is required to avoid cavitation.
DO NOT RUN
DRY.
3. Connect the high-pressure hose to the outlet fitting located on
the side of the boiler housing.
4. Connect the gun to the high-pressure hose.
5. Insert the dip tube into a container of soap or chemical, if used.
See " SOAP OR CHEMICAL APPLICATION" for a more
detailed explanation on using soap or chemicals.
6. Turn on the water supply, and with no quick disconnect nozzle
in place, trigger the gun for a few minutes to allow trapped air,
dirt particles or mill scale to escape from the system. Reinstall
the desired quick disconnect nozzle.
NOTE:
Always be sure when operating the machine that the
nozzle is not clogged or restricted in any way.
CAUTION:
ALWAYS ENGAGE THE TRIGGER LOCK WHEN
CHANGING NOZZLES.