WARNING:
NEVER PUT GASOLINE IN THE BURNER FUEL
TANK.
WARNING:
DO NOT WRAP HOSES OR ELECTRICAL
CORDS AROUND THE BOILER HOUSING. DAMAGE AND
SERIOUS INJURY MAY RESULT
BOILER/BURNER SAFETY
1.
Keep combustible materials a minimum of 48" (1200 mm)
from the sides of the boiler housing.
2.
Do not install a stack pipe on this product as it will impede
airflow resulting in poor combustion and possible release of
harmful fumes.
3.
Do not exhaust gasses into a wall, ceiling, or confined space.
4.
The use of a ducted exhaust hood is recommended for indoor
operation. Otherwise, place the power unit outside the
building. Do not, however, expose the machine to rain.
5.
Always be mindful that there is an open flame at the top of the
boiler when the burner is firing. Keep hands, hair, clothing
and other combustible materials away.
FUEL OIL FILTER
The HPW-1500G is equipped with a micron fuel oil filter, which is
located on the fuel oil line under the machine housing. The fuel oil
tank is also equipped with a filter to trap larger pieces of debris,
which may get into the fuel oil supply. The micron filter should be
changed and the fuel oil tank cleaned annually.
23
23