[page 20] | gpelectric.com
Menu Heading
Selections / Adjustments Range
Default Setting
Unit Readings
DC
11.68V
0.0A
Read Only
AC INPUT
0 A
0 V
0 Hz
VAC OUT
120 V
60.0 Hz
Temperature
Batt: 20.0°C
Trans: 30.5°C
Fets: 30.6°C
1. DC STATUS
The first value: 11.68 V displays the voltage (VDC) from the battery bank connected to the
Inverter/Charger
. This reading is displayed
with a 0.01 VDC resolution.
SHORE POWER
UNIT READINGS
INVERTER
ON/OFF
CHARGER
ON/OFF
ENTER / SET
BACK
UNIT SETUP
REMOTE SETTINGS
®
SHORE POWER
UNIT READINGS
INVERTER
ON/OFF
CHARGER
ON/OFF
ENTER / SET
BACK
UNIT SETUP
REMOTE SETTINGS
®
SHORE POWER
UNIT READINGS
INVERTER
ON/OFF
CHARGER
ON/OFF
ENTER / SET
BACK
UNIT SETUP
REMOTE SETTINGS
®
DC Status
11.68 V
0.0 A
AC INPUT
0 A
0 V
0 Hz
VAC OUT
120 V
60.0 Hz
The second value: 0.0A displays the battery current (VDC) either being dis-
charged (inverting mode) or charged (charging mode) from/into the battery
bank.
A negative value, e.g. -35.0A shows that the batteries are dis-charging and
the
Inverter/Charger
is inverting.
A positive value, e.g. 40.0A shows that the batteries are charging and the
Inverter/Charger
is in charging mode.
State indicator: PT - Pass Through; PS - Powershare; CHG - Charging; INV:
Inverting
2. AC INPUT
The first value is showing the total AC Amps being used by the inverter for
charging and for powering any AC Loads. This reading is always displayed
as a positive number. If the charger is using 15A to charge the batteries
and the connected AC load is using 10A then the total AC Input value is
displayed as 25A.
The second value is showing the voltage (AC) of the connected AC Power
source (Utility or Generator). This will usually read 120V.
The third value is showing the frequency of the connected AC Power source
(Utility or Generator). This is displayed as a unit of frequency: Hertz (Hz).
3. VAC OUT
The first value displays the AC voltage measurement at the inverters output
terminals.
When in inverting mode this reading is displaying the inverters output
voltage.
When in charging or AC pass through mode, the display is showing the AC
voltage that is passing through the
Inverter/Charger
from the AC power source
(utility or generator)
PT
OPERATION
Содержание DOMETIC GP-ICR-50
Страница 31: ......