gpelectric.com | [page 21]
SHORE POWER
UNIT READINGS
INVERTER
ON/OFF
CHARGER
ON/OFF
ENTER / SET
BACK
UNIT SETUP
REMOTE SETTINGS
®
SHORE POWER
UNIT READINGS
INVERTER
ON/OFF
CHARGER
ON/OFF
ENTER / SET
BACK
UNIT SETUP
REMOTE SETTINGS
®
Temperature
Batt : 20.0°C
Trans : 30.5°C
Fets : 30.6°C
Unit Fault Code
No Fault
4. TEMPERATURE
Batt:
Displays the temperature of the
Inverter/Charger
battery temp sensor
which should be connected to the battery bank
Trans:
Displays the temperature of the main power transformer inside the
Inverter/Charger
.
Fets:
Displays the temperature of the field effect transistors (FETs) inside
the
Inverter/Charger
.
4.5 UNIT SETUP MENU
Menu Heading
Selections / Adjustments Range
Default Setting
Unit Setup
01 Search Watts
OFF, 5 - 50W
5W
02 LowBatCutOut
9.0 - 12.2 VDC
10.5 VDC
03 VAC Dropout
80 - 100V
85V
04 Max.Cha Time
0.0 - 25.5 HR
12.0 HR
05 Battery Type
Gel, Flooded, AGM 1, AGM 2, Custom
AGM 1
06 Charge Rate
50% (IC 2000); 40% (IC 3000)
80%
07 Final Charge
Multi-Stage, Float, Silent
Multi-Stage
08 ABS Chg Time
0.5 - 24.0 HR
2.0 HR
09 Equalization
Active/Inactive
Inactive
10 Rebulk Volt
12.0 - 16.0 VDC
12.1 VDC
5. FAULT CODE
This screen will display a code to compliment the audible beep that is emitted
when a fault has occurred. If there are no faults, this screen will say
No Fault
.
OPERATION