background image

GlideScope

®

 Cobalt AVL System

8

User’s Manual

The GlideScope Cobalt AVL System is an ideal tool for physicians and other 

health care professionals who need to effectively manage standard to dif-

ficult airways. It is useful for the intubation of normal airways, anterior 

airways, neonatal patients, obese patients, and patients with limited neck 

extension. Additionally, it is useful for teaching purposes, verification of  

endotracheal tube (ETT) placement, nasal intubation, and ETT exchange. 

The Cobalt AVL is easy to learn, use, and teach. It is ideal for acute care  

settings and emergency environments. It also integrates into standard  

ED, OR, ICU, and NICU applications.

The Cobalt AVL can be used with a combination of video batons and GVL

®

 

Stats. Single-use GVL Stats are offered in a comprehensive range of sizes, al-

lowing clinicians to meet the particular requirements of patients ranging in 

size from preterm infants to morbidly obese adults.

The Cobalt AVL System is recommended for use with an endotracheal tube 

stylet, particularly the GlideRite

®

 Rigid Stylet which complements the AVL 

blade angle.

The System may include the following components:

•  Cobalt AVL Monitor
•  Cobalt AVL Video Baton 1-2 (for neonatal patients)
 

–  GVL 0 Stat (patients less than 1.5 kg)* 

 

–  GVL 1 Stat (patients between 1.5–3.6 kg)*

 

–  GVL 2 Stat (patients between 1.8–10 kg)*

•  Cobalt AVL Video Baton 3-4  (for use on children and adults)

  –  GVL 3 Stat (patients between 10 kg–Adult)*
  –  GVL 4 Stat (patients between 40 kg–Morbidly obese)*

•  GlideRite Rigid Stylet (recommended)

* Weight ranges are approximate; a medical professional must evaluate on a 

patient-by-patient basis.

Product Information

Содержание Cobalt AVL

Страница 1: ...GlideScope Cobalt AVL System User s Manual and Quick Reference Guide 0900 2654 04 20...

Страница 2: ...GlideScope Cobalt AVL System Quick Reference Guide...

Страница 3: ...e trademarks of Verathon Inc All other brand and product names are trademarks of their respective owners The GlideScope technology is covered under US Patents 6 655 377 6 543 447 as well as European P...

Страница 4: ...on the video socket Insert the cable into the socket you will hear a click when successfully connected Insert the video baton into the GVL Stat Ensure that the GlideScope logos on the video baton and...

Страница 5: ...on appears above the button that cancels the current operation moves to the previous screen or returns to the main menu Progress Confirmation these animations show the Cobalt AVL system s progress whe...

Страница 6: ...nto the patient s mouth not at the screen carefully guide the distal tip of the tube into position near the tip of the laryngoscope It is important to look into the mouth at this step to avoid injurin...

Страница 7: ...heal tube withdraw the stylet approx 5 cm while gently advancing the ETT A 1 cm adjustment withdrawal of the laryngoscope also may be beneficial to reduce the viewing angle and allow the glottis to dr...

Страница 8: ...an enzymatic debridement agent detergent to remove all foreign material from the surface of the device 4 The video baton can now be disinfected Cleaning and Disinfecting the Monitor Clean the exterior...

Страница 9: ...ucous membranes and non intact skin by the Stat sterile single use when used as intended Low Level Disinfection is recommended for the Cobalt AVL Video Baton after every patient use High Level Disinfe...

Страница 10: ...al tubes 6 0 mm and larger REUSABLE SINGLE USE STATS GVL Size GVL 2 GVL 3 GVL 4 GVL 5 GVL 0 GVL 1 GVL 2 GVL 3 GVL 4 Patient Weight 1 8 10 kg 10 kg Adult 40 kg Morbidly Obese 40 kg Morbidly Obese 1 5 k...

Страница 11: ...ht at camera 15mm Width at camera 18mm REUSABLE SYSTEM COMPONENTS GVL 5 Length blade tip to handle 103mm Height at camera 14mm Width at camera 27mm GVL 4 Length blade tip to handle 103mm Height at cam...

Страница 12: ...mage Do not expose GlideScope Cobalt AVL System to temperatures above 60 C 140 F Do not use autoclaves or pasteurizers for the Cobalt AVL System Use of such methods to disinfect GlideScope Cobalt AVL...

Страница 13: ...alt AVL Video Baton connects directly to a full color digital video monitor for real time viewing The System may include the following components Cobalt AVL Monitor Cobalt AVL Video Baton 1 2 for neon...

Страница 14: ...L Button Panel Power press and release to turn on the Cobalt AVL Press and hold for three seconds to turn off the Cobalt AVL Record press to start and stop recording When you are recording the Record...

Страница 15: ...s to download all new recordings not previously downloaded Download All indicates which button to press to download all video recordings Cancel Download indicates which button to press to cancel downl...

Страница 16: ...e Video Out Port Connect the HDMI to DVI cable from the external monitor Mounting Plate Use this plate to connect the monitor to mobile stand or IV pole Product Identification Includes product serial...

Страница 17: ...rs on the monitor screen 5 Press the Record button to start or stop recording 6 Reference the GlideScope4 Step Technique to perform intubations 7 Optional Download video to the USB drive Note If the C...

Страница 18: ...to the power supply Connectors and cable insulation integrity To ensure patient safety users should perform a routine inspection of the GlideScope Cobalt AVL Video Baton before every use to ensure th...

Страница 19: ...te The Cobalt AVL Video Baton is a nonsterile reusable device which is protected from contact with mucous membranes and non intact skin by the Stat sterile single use when used as intended Low Level D...

Страница 20: ...ructions High Ortho Phthalaldehyde 0 55 0 55 exposure for 12 minutes at 20 C or as per manufacturer s instructions High Peracetic Acid 0 2 0 2 exposure for minimum 12 minutes at 50 to 56 C or as per m...

Страница 21: ...araldehyde Up to 3 4 2 0 exposure for minimum 20 minutes at 20 C or as per manufacturer s instructions High Ortho Phthalaldehyde 0 55 0 55 exposure for 12 minutes at 20 C or as per manufacturer s inst...

Страница 22: ...Cleaning the GlideScope Cobalt AVL Video Baton The GlideScope Cobalt AVL Video Baton which is protected by the GVL Stat is not intended to have direct patient contact Caution Do not place the GlideSc...

Страница 23: ...with WEEE requirements Cleaning the GlideScopeCobalt AVL Monitor Wipe the exterior of the monitor with IPA 70 isopropyl alcohol bleach 100 ppm or a mild detergent and water Cleaning the GlideScopeCoba...

Страница 24: ...Medical Device Directive 0413 for Sterile Devices Canadian Standards Association CSA mark of certification to applicable standards for electromedical equipment Tested to Federal Communications Require...

Страница 25: ...Pressure 440 1060 hPa Shipping and Storage Conditions Temperature 20 C to 45 C Relative Humidity 0 to 95 Atmospheric Pressure 440 1060 hPa Charging Conditions Temperature 0 C to 40 C Relative Humidit...

Страница 26: ......

Страница 27: ...GlideScope Cobalt AVL System User s Manual...

Страница 28: ......

Страница 29: ...GlideScope Cobalt AVL System User s Manual...

Страница 30: ......

Страница 31: ...Connect the Video Baton 18 Insert the Video Baton into the GVL Stat 18 GlideScope Anti Fog Feature 19 Connect to an External Monitor Optional 19 Perform a Functional Check 20 Set the GlideScope Cobal...

Страница 32: ...deo Baton 41 Cleaning the GlideScope Cobalt AVL Monitor 41 Cleaning the GlideScope Cobalt AVL Cradle 41 Cleaning and Disinfecting the GlideRite Rigid Stylet 42 Replacing the GlideScope Monitor Battery...

Страница 33: ...ts directly to a full color digital video monitor for real time viewing The monitor can store up to one 1 hour of video approximately 40 typical intubations which you can download to a USB drive for a...

Страница 34: ...o batons and GVL Stats Single use GVL Stats are offered in a comprehensive range of sizes al lowing clinicians to meet the particular requirements of patients ranging in size from preterm infants to m...

Страница 35: ...cumentation of the laryngoscopy Nasal tracheal intubation Insertion of transesophageal echocardiac probes Laryngoscopic foreign body removal Awake intubation for difficult airway management Insertion...

Страница 36: ...AVL System to temperatures above 60 C 140 F Do not use autoclaves or pasteurizers for the Cobalt AVL System Use of such methods to disinfect GlideScope Cobalt AVL System will cause permanent device da...

Страница 37: ...ation However there is no guarantee that interference will not occur in a particular installation Interference can be determined by turning the device on and off If this device does cause interference...

Страница 38: ...ght denotes the key has been activated Tutorial press and hold for three seconds to play the GlideScope 4 Step Technique tutorial The main component of GlideScope Cobalt AVL System is the digital full...

Страница 39: ...all new recordings not previously downloaded Download All indicates which button to press to download all video recordings Cancel Download indicates which button to press to cancel download USB Not F...

Страница 40: ...ort Connect a USB drive to down load video Video Baton Port Connect the video baton cable Video Out Port Connect the HDMI to DVI cable from the external monitor Mounting Plate Use this plate to connec...

Страница 41: ...obalt AVL Monitor using the 12VDC Medical Power Supply provided only by Verathon 4 Connect a video baton to the monitor and when preparing for intuba tion insert the baton into a Cobalt GVL Stat For s...

Страница 42: ...30 68 70 570 Europe For additional contact information see page 50 GlideScope Cobalt AVL System Configurations You can set up the GlideScope Cobalt AVL System in two configurations Mount it on a mobil...

Страница 43: ...charged Approximately 1 3 battery life remaining Approximately 2 3 battery life remaining Battery is 2 3 to fully charged Charge the Monitor Battery The Cobalt AVL monitor includes a lithium battery V...

Страница 44: ...eed 41 C at the tip of the baton where the lighting and camera are located Insert the Video Baton into the GVL Stat To insert the Cobalt AVL Video Baton into the sterile single use GVL Stat 1 Before y...

Страница 45: ...Figure 10 Connect one end of the video output cable to the HDMI socket Getting Started GlideScope Anti Fog Feature To ensure optimal results of the anti fog heating feature on the GlideScope video lar...

Страница 46: ...nel of the monitor 4 Look at the monitor screen to verify that an image is being received from the video baton Note When you insert the video baton into a GVL Stat a small portion of the stat appears...

Страница 47: ...ters 1 Press and release the Power button 2 Immediately within two seconds press and hold the External Video and Tutorial button simultaneously until processing update text message appears at the top...

Страница 48: ...o ways On a mobile stand Figure 13 On an IV pole Figure 16 Set Up the Cobalt AVL on a Mobile Stand You can set up the Cobalt AVL System on a mobile stand The stand makes it easy for you to move the sy...

Страница 49: ...the black height adjust ment knob counterclockwise 2 Raise or lower the pole to the desired height 3 Turn the knob clockwise to secure the pole at the desired height Adjust the Height of the Mobile St...

Страница 50: ...e quick release mount Angle adjustment knob Quick release lever in locked position Locking pin in unlocked position Adjust the Monitor Angle Before you start using the GlideScope adjust the angle of t...

Страница 51: ...cope Video Baton Cradle to the GVL Cradle 1 Hook the video baton cradle into the GVL Cradle Figure 17 To attach the GlideScope Video Baton Cradle directly to the mobile stand or IV pole 1 Screw the ce...

Страница 52: ...e to the back panel of the monitor Figure 15 3 Make sure the quick release lever is in the release horizontal position 4 Slide the monitor onto the quick release mount 5 Press the quick release lever...

Страница 53: ...eScope 4 Step Technique to perform intubations on page 32 7 Optional Download video to the USB drive Select the Correct Video Baton and Stat Make sure that you select the Cobalt AVL Video Baton and GV...

Страница 54: ...arrow on the video baton cable with the arrow on the video socket 2 Insert the cable into the socket You will hear a click when the cable is successfully connected Note When disconnecting the connecto...

Страница 55: ...VL GlideScope Anti Fog Feature To ensure optimal results of the anti fog heating feature on the GlideScope video laryngoscope perform the following steps 1 Prior to use open the GVL Stat pouch but do...

Страница 56: ...corner of the monitor screen as a frame of reference Look at the monitor screen to verify that an image is being received from the video baton Figure 27 Frame of reference The GVL Stat is a sterile s...

Страница 57: ...he Cobalt AVL System records video using memory inside the monitor 1 Power on the system 2 To start recording press the Record button 3 When you are ready to stop recording press the Record button aga...

Страница 58: ...d the GVL Stat are designed to be inserted down the midline of the tongue to the epiglottis The Cobalt AVL Video Baton with a GVL Stat may be used to produce a Macintosh style lift of the epiglottis o...

Страница 59: ...ottis by the Cobalt AVL Stat Maximum laryngeal exposure may not facilitate intubation reducing the elevation applied to the laryngoscope may make inserting the ET tube easier Tips for Working with End...

Страница 60: ...drive has sufficient memory to store the video files you want to download A minimum of 1 GB USB Drive is required to download all files To start downloading video files press the Download button Thre...

Страница 61: ...ctors and cable insulation integrity To ensure patient safety users should perform a routine inspection of the GlideScope Cobalt AVL Video Baton before every use to ensure that all endoscopic componen...

Страница 62: ...s in all applications Device Sterile Use Spaulding s CDC Classification Disinfection Sterilization Low Level Int Level High Level Video Baton Non sterile Reusable Noncritical X GVL Stat Sterile Single...

Страница 63: ...igh Ortho Phthalaldehyde 0 55 0 55 exposure for 12 minutes at 20 C or as per manufacturer s instructions High Peracetic Acid 0 2 0 2 exposure for minimum 12 minutes at 5 56 C or as per manufacturer s...

Страница 64: ...tions See comments on right Classified as a chemical sterilant Isopropyl Alcohol Solution 70 70 exposure for 10 minutes at 20 C Intermediate 70 used to wipe down with minimum 1 minute exposure Low Ble...

Страница 65: ...the product is exposed to temperatures above 60 C 140 F Figure 33 Monitor the color of temperature indicator to avoid overheating the Cobalt AVL Video Baton Temperature indicator Cleaning the Cobalt A...

Страница 66: ...an corrode the stainless steel inserts and damage the connector pins You can also use a soft brush to scrub the video baton taking care not to damage the camera lens However do not use a wire brush be...

Страница 67: ...ration and temperature recommended by the disinfectant manufacturer Disinfect the equip ment following the disinfectant manufacturer s instructions or as stated in Table 3 on page 37 4 After the disin...

Страница 68: ...e it has been determined that the GlideRite Rigid Stylet is compatible with the autoclaving cycle in Table 4 on page 38 Replacing the GlideScope Monitor Battery Under normal operating conditions the m...

Страница 69: ...agrees to send the defective unit to Verathon cleaned and disinfected as appropriate upon receipt of the loaner unit and the customer agrees to return the loaner unit within two 2 business days of rec...

Страница 70: ...isclaimer of Additional Warranties There are no understandings agreements representations of warranties expressed or implied including warranties of merchantability or fitness for a particular purpose...

Страница 71: ...ective 0413 for Sterile Devices Canadian Standards Association CSA mark of certification to applicable standards for electromedical equipment Tested to Federal Communications Commission Requirements C...

Страница 72: ...ght at camera 9 mm Width at camera 9 mm Max blade width in front of camera 9 mm GVL Stat 1 Length blade tip to handle 44 mm Height at camera 9 mm Width at camera 10 mm Max blade width in front of came...

Страница 73: ...T Stylet Handle Length 31 mm Handle Width 40 mm Stylet Rod Length 394 mm Distal Tip Diameter 5 mm GlideRite Guide Height 190 mm Width 98 mm Thickness 15 mm IV Pole Mount Weight 0 9 kg Arm Length 27 cm...

Страница 74: ...060 hPa Shipping and Storage Conditions Temperature 20 C to 45 C Relative Humidity 0 to 95 Atmospheric Pressure 440 1060 hPa Charging Conditions Temperature 0 C to 40 C Relative Humidity 0 to 95 Atmos...

Страница 75: ...le 0810 0126 GlideScope Video Baton Cradle 1 2 0810 0151 GlideScope Video Baton Cradle 3 4 0810 0134 Cobalt AVL Mobile Stand 0800 0410 Cobalt AVL IV Pole Mounting Kit 0810 0200 Universal Accessory Bas...

Страница 76: ...e Headquarters 20001 North Creek Parkway Bothell WA 98011 U S A 800 331 2313 US and Canada only 425 867 1348 Fax 425 883 2896 verathon com Manufacturer Verathon Medical Canada ULC 4224 Manor Street Bu...

Страница 77: ......