Relays/actuators – what switches when?
The following rules apply with the basic configuration of
the switching actuator assignments:
• the relays of the fingerprint reader are not switched as
soon as a switching actuator is assigned.
• an individual switching actuator always has a higher
priority than a group switching actuator.
Extended configuration
In the basic configuration a user finger switches only the
assigned switching actuator. If this user finger addition-
ally triggers the "group actuator" or a relay, the user fin-
ger is assigned a special mode:
* Factory setting
Individual actuator
Group actuator
Relay
not assigned
not assigned
switches
not assigned
assigned - switches
does not switch
assigned - switches
assigned – does not
switch
does not switch
Mode
Assigned
individual actuator
Assigned
group actuator Assigned relay
1*
switches
does not switch does not switch
2
switches
switches
does not switch
3
switches
does not switch
switches
4
switches
switches
switches