Assignment of user -
group switching actuator/door opener
Assigning all taught-in user fingers in the fingerprint
reader to a group switching actuator:
1. Press the "Systemprogr." button on the control device
for 3 secs. to start programming mode.
3
The LED at the control devices flashes.
The fingerprint reader generates an acknowledgement
tone and the LED flashes orange. The operating mode
LED of the switching actuator flashes.
2. Press the button "Progr." at the switching actuator
(or the button "Türöffnerprogr." of the control device),
until the LED next to the button flashes.
3
The fingerprint reader again generates an acknowl-
edgement tone.
3. Lay on admin finger.
3
The fingerprint reader generates a positive acknowl-
edgement signal.
The switching actuator was assigned successfully.
4. Press the "Systemprogr." button on the control device
to exit the programming mode.
i
Delete assignment of user -
switching actuator
To delete the user - switching actuator assignment, the
teach-in procedure is repeated.
The assignment cannot be deleted via the switching
actuator (press programming button 6 secs.).