12
Model:
Installation
Installation
2-04.2.3
Electrical Connection, 120V to 480V Appliance Power Separate from
208-240V Hood Power w/Remote Shunt Trip Device
120V to 480V APPLIANCE POWER SEPARATE FROM 208-240 V HOOD POWER (USING REMOTE
SHUNT TRIP CONTACTOR SUPPLIED BY LICENSED ELECTRICIAN). Contactor must be a UL Listed,
definite purpose, AC resistive, air heating type, suitable for the appliance load. The Installation and
connections shall be in accordance with the National Electric Code NFPA 70.
208-240V HOOD POWER
APPLIANCE POWER &
CONTACTOR COIL SIGNAL TO
SHUNT TRIP DEVICE
USE LIQUID-
TIGHT CONDUIT
AND FITTINGS