5
Model: OVH-10-C
1. Do not obstruct the exhaust air outlet. Maintain a minimum clearance of
18 inches (457.2 mm)
between the air outlet and the ceiling, or any other overhead obstruction.
2. The OVH-10-C Hood model is designed to sit atop a counter space. Ensure that the intended site is
structurally sound and capable of supporting the hood’s weight plus that of the appliance(s) to be
placed under it. See
Section 1-4.3, Hood Weight.
2-02.
Location
NOTE:
•
The sound level of the hood while operating will be approximately 65 dB.
•
DO NOT MODIFY OR ALTER THIS EQUIPMENT, OR ADD ATTACHMENTS OF ANY KIND.
!
CAUTION
NOTE:
•
For some installations, it may be necessary to consult a HVAC specialist to
confirm that proper room air exchange is occurring and that the on-site A/C
system is capable of handling the anticipated heat load.
•
Exhaust ventilation is recommended for areas in which recirculating hoods are operated. Giles
recommends
50 CFM
per linear foot of hood space.
This amount could vary based on local codes
and site-specific situations
.
Model: OVH-10-C