8
Model:
Installation
Installation
2-04.
Electrical Requirements
Power Rating for Hood Only, if Appliance is on Separate Circuit & Interlocked
Through Separate Contactor
Voltage
Hz
Phase
Hood Power
(Amps)
Breaker
208-240
60
1
1.5
15
•
Consult a qualified electrician to ensure that all electrical specifications have been met and that the
unit is properly grounded.
•
Improper installation, adjustment, alteration, service or maintenance could result in serious injury or
even death, damage to equipment or property, and void the warranty.
!
WARNING
Power Rating for Hood & Appliance** on Same 208-240V Circuit
Voltage
Hz
Phase
Field Provided Appliance
Power (Amps)
Hood Power
(Amps)
Branch Circuit Protector
(Amps) if Connecting
Hood & Appliance on
Same Circuit
208-240
60
1 or 3
0 - 10.5
1.5
15
10.6 - 14.5
1.5
20
14.6 - 22.5
1.5
30
22.6 - 38.5
1.5
50
38.6 - 46.5
1.5
60
46.7 - 50
*
1.5
70
*
Appliance(s) exceeding 50A must have a separate circuit from the Hood, but be intelocked through the
Hood contactor coil.
**
Appliance provided and rated separately from Hood.
Содержание OVH-10-C
Страница 2: ......
Страница 4: ......
Страница 26: ...Model OVH 10 C Overview 16 3 01 Control Panel 2 1 ILS Only 7 6 5 3 9 4 8 ...
Страница 28: ...18 Model OVH 10 C Overview 3 02 Hood Front Filter Chamber 1 4 3 2 5 6 Not Shown ...
Страница 32: ...22 Model OVH 10 C Overview NOTES ...
Страница 40: ...Operation Filter Maintenance Model OVH 10 C 30 NOTES ...
Страница 44: ...34 Model OVH 10 C Hood Cleaning Maintenance Notes ...
Страница 52: ...NOTES Parts List Model OVH 10 C 42 ...
Страница 53: ......