27
This section describes starting the ventless hood. Be sure that all filters are in place and properly seated before
attempting to start.
Hood will not start unless the Filter Access Cover is in position and secured properly
.
1
3
2
4
This section explains hood operation and filter maintenance procedures.
1. Press and momentarily hold the top
[START]
portion of the
Power Switch
①
until
the hood blower starts running. Release and the switch will spring back and
remain ON.
2 The green
HOOD POWER
light
②
and the small
EAC [ON]
light
③
should both
turn ON. A constant tone alarm may sound briefly and then silence as the fan
reaches full speed.
3. At that time, the amber
FRYER POWERED
light
④
should turn ON, indicating that
power is now being supplied to the fryer and it is ready for use.
Should this sequence not occur or should any other lights turn ON
, see the
Section 7,
Troubleshooting
for possible cause and corrective action.
4.
Operation
4.01 Hood Operation
4.02
Filter System Overview
4.02.1
Ventless Hood Filter Table
Filter
When to
Clean/Replace
How to Remove
How to Clean
How to Install
Baffle Filter
Clean daily
Section 4.02.2
Section 5.01.1
Section 4.02.3
E.A.C. Collector Cell
Clean daily
Section 4.02.4
Section 5.01.2
Section 4.02.5
HEPA
Filter
(Optional)
Change as needed
DO NOT
CLEAN
Section 4.02.4
DO
NOT ATTEMPT TO
CLEAN...REPLACE ONLY!
Section 5.01.4
Section 4.02.5
Charcoal Filter
Replace every 30 to 40
days (approx.)
Section 4.02.6
DO NOT ATTEMPT TO
CLEAN...REPLACE ONLY!
Section 5.01.3
Section 4.02.6
Starting the Hood:
1. Press the bottom
[OFF]
portion of the
Power Switch
①
.
2 Blower stops and all indicator lights turn
OFF
.
3. Power to the fryer is shutdown.
Shutdown the Hood:
Operation
FSH-2-PH
Содержание FSH-2-PH
Страница 4: ......
Страница 14: ...4 Introduction FSH 2 PH ...
Страница 36: ...26 Overview FSH 2 PH ...
Страница 45: ...35 Operation FSH 2 PH NOTES ...
Страница 53: ...43 Cleaning Maintenance FSH 2 PH ...
Страница 56: ...46 Troubleshooting FSH 2 PH ...
Страница 58: ...48 Parts List FSH 2 PH 1 2 3 5 6 8 7 4 Not shown 7 02 Ventless Hood Front ...
Страница 60: ...50 Parts List FSH 2 PH 4 7 5 6 1 2 3 8 9 10 11 12 13 14 15 ILS Only Not Shown 7 03 Control Box ...
Страница 62: ...52 Parts List FSH 2 PH 3 4 1 2 6 10 7 9 11 13 12 5 8 17 14 16 18 19 20 21 22 23 24 15 7 04 Ventless Hood Rear ...
Страница 64: ...54 Parts List FSH 2 PH Notes ...
Страница 65: ......