33
Operation
FSH-2-PH
4.03.3
E.A.C. Filter Status & Alarm
[ON]
Indicates that the E.A.C. cell is installed, powered and operating. It will be the only light ON
if the cleaning
system is operating normally.
[WASH]
This light turns ON to indicate the following:
• Filter cell is not installed or is mis
aligned.
• Collection fins contain excessive amount of captured grease residue.
• There is poor contact with contact plate inside hood.
• Too many Ionizer wires are missing.
When the
[WASH]
light is ON, an alarm condition exists and air cleaner is not
functioning. After approximately two (2) minutes, a beeping alarm tone begins
sounding and shortly thereafter, power to the fryer under the hood is
shutdown; the
[FRYER POWER]
light turns OFF.
[WASH]
light is
NOT
intented to be used as a signal for routine cleaning of the
cell ...
DO NOT use as such
. Typically, the collector cell must be cleaned
DAILY
to ensure optimum performance. See
Section 5.01.2, EAC Filter Cell Cleaning
.
[CHECK]
This light turns ON to indicate the following:
• A broken ionizer wire is touching the cell frame.
• The cell is damaged & shorted to ground.
• Collection fins are shorted because of excessive moisture.
When
[CHECK]
light is ON
,
system is no longer functioning to clean the air, even
though the hood continues to run and fryer remains powered.
DO NOT
CONTINUE TO USE FRYER WHEN THIS CONDITION EXIST ... CEASE COOKING &
PREFORM AN INSPECTION!
The following actions may clear alarm conditions:
1. Turn OFF hood
Power Switch
.
2. Remove the E.A.C. cell and clean as described in
Section 5.01.2
.
3. Inspect the cell for broken or missing ionizer wires, bent fins, or other damage. Ionizer wires are replaceable
(when ordering replacements, note length ...
20”
). Bent fins may be gently straightened by hand, so that no fin
is touching an adjacent fin. A cell with excessive damage (broken or badly bent frame, broken insulators, etc)
must be replaced.
4. Inspect the E.A.C. contact plate inside hood. Clean grease accumulation away with a mild degreasing cleaner
and dry thoroughly.
5. Replace filter cell
(
Section 4.02.5
)
and restart Hood
(Section 4.01)
. If the condition persist, contact a qualified
service technician.
If none of the LED lights turn ON when hood is started, the power supply may be faulty ... service is required.
Three LED lights on the control box panel indicate the operational status of the
Electronic Air Cleaner (E.A.C.)
system.
Содержание FSH-2-PH
Страница 4: ......
Страница 14: ...4 Introduction FSH 2 PH ...
Страница 36: ...26 Overview FSH 2 PH ...
Страница 45: ...35 Operation FSH 2 PH NOTES ...
Страница 53: ...43 Cleaning Maintenance FSH 2 PH ...
Страница 56: ...46 Troubleshooting FSH 2 PH ...
Страница 58: ...48 Parts List FSH 2 PH 1 2 3 5 6 8 7 4 Not shown 7 02 Ventless Hood Front ...
Страница 60: ...50 Parts List FSH 2 PH 4 7 5 6 1 2 3 8 9 10 11 12 13 14 15 ILS Only Not Shown 7 03 Control Box ...
Страница 62: ...52 Parts List FSH 2 PH 3 4 1 2 6 10 7 9 11 13 12 5 8 17 14 16 18 19 20 21 22 23 24 15 7 04 Ventless Hood Rear ...
Страница 64: ...54 Parts List FSH 2 PH Notes ...
Страница 65: ......