21
Overview
FSH-2-PH
Item
Description
Function
*
1
Filter Access Cover
Covers the filter chamber and plenum. Easily removed for
access. Hood & fryer will not operate unless this cover is in
place and properly latched.
2
Charcoal Filter
Helps to control undesirable cooking aromas. It should be
replaced monthly (approx.).
DO NOT attempt to clean & re
‐
use filter
.
Have a standby filter
(Giles #30248)
for quick
exchange to avoid lost time!
NO FILTER WILL
COMPLETELY ELIMINATE COOKING ODOR.
3
Electronic Air Cleaner (E.A.C.)
Collection Cell
The E.A.C. system is an electronic air cleaner that
electrostatically captures grease vapor and smoke particulate
generated when cooking.
Power must be turned OFF before
removing the cell for cleaning. To maintain best hood
performance, cell must be cleaned daily. Fryer under hood
will be disabled if cell is not in place, becomes excessively
dirty, or is experiencing other faults.
**
4
HEPA
Filter
(Optional)
ONLY
this version is CE listed
Optional:
High
efficiency
HEAP Filter
alternative. The filter
CANNOT
be cleaned and must be replaced periodically to
maintain acceptable performance.
Fryer under hood will be
disabled if the HEPA
Filter is not in place or becomes clogged. HEPA Filter
positioning is the reverse of what is shown ... charcoal filter
is located below the HEPA
filter.
5
Baffle Filter
First stage of the air cleaning system. Easily removed for
daily cleaning.
To prevent contact with electrical parts and
avoid electrical shock,
DO NOT
remove the baffle filter
while hood and fryer are powered.
6
Grease Drip Cup
Collects and holds grease condensate generated by the
baffle filter. It should be cleaned daily, or as needed.
7
Grease Drip Cup Safety Pin
Secures the grease drip cup in place to prevent it from
unintentionally falling from the holding bracket.
8
Discharge Air Diverter
Diverts hood exhaust air to the sides and rear. Allows for
operation of the unit in spaces with lower ceiling heights.
*9
Appliance Fusible Detector Link
A fire in fry vat melts the detector link and trips the fire
extinguishing system. To avoid accidental system
discharge, take care not to hit the link.
*
Not Shown
**
CE Listed Models require HEPA
Filter
3.01 Filter Chamber & Hood Front
Содержание FSH-2-PH
Страница 4: ......
Страница 14: ...4 Introduction FSH 2 PH ...
Страница 36: ...26 Overview FSH 2 PH ...
Страница 45: ...35 Operation FSH 2 PH NOTES ...
Страница 53: ...43 Cleaning Maintenance FSH 2 PH ...
Страница 56: ...46 Troubleshooting FSH 2 PH ...
Страница 58: ...48 Parts List FSH 2 PH 1 2 3 5 6 8 7 4 Not shown 7 02 Ventless Hood Front ...
Страница 60: ...50 Parts List FSH 2 PH 4 7 5 6 1 2 3 8 9 10 11 12 13 14 15 ILS Only Not Shown 7 03 Control Box ...
Страница 62: ...52 Parts List FSH 2 PH 3 4 1 2 6 10 7 9 11 13 12 5 8 17 14 16 18 19 20 21 22 23 24 15 7 04 Ventless Hood Rear ...
Страница 64: ...54 Parts List FSH 2 PH Notes ...
Страница 65: ......