Error Messages
The following error messages can be displayed during modem installation.
The table below offers possible causes and resolution methods.
#
Error Message /
Description
Error Cause
Resolution
1
RF Cluster code value is
out of range
Invalid RF Cluster
code entered
Enter correct RF Cluster
code
2
Location code value is out
of range
Invalid Location
code entered
Enter correct Location code
3
On clicking Next in the
first page of Install:
Rx cable is not connected
properly.
CPE has detected
the Rx cable
disconnect
Verify:
Rx cable connected to RF
In port on modem
Rx cable indoor end
assembled correctly to
connector
Rx cable connected to Rx
port on Transceiver
If the problem persists
contact operator
4
In Step 2 of installation,
the following error dialog
is shown:
Configuration mismatch
detected!
CPE has detected
that the RF cluster
code does not match
the kit provided
Verify the installation
parameters. If the
parameters are correct,
contact Help Desk.
5
When Finish Pointing
button is clicked in Step 2
of installation and dish
status is Not Locked:
Modem must be locked
before ending pointing.
Modem is not locked Achieve modem locking
6
Step 3, substep 1/5:
software download
timeout
Modem cannot
complete software
download
Check the Rx/Tx cable
connection
Restart activation
7
Step 3, substep 3/5:
Return Channel
Acquisition timeout
Modem cannot
complete Return
Channel Acquisition
Restart activation; if the
problem persists, contact
Help Desk
8
Step 3, substep 4/5:
Network Admission
timeout
Modem cannot
complete Network
Admission
Restart activation; if the
problem persists, contact
Help Desk
9
In Step 3 of installation,
the following error dialog
is shown:
Note: [step name] is
taking longer than
expected.
Timeout
Contact the Help Desk (see
contact info in the manual
provided with the kit).
Once the problem is
resolved, click Restart
Activation.
Содержание SkyEdge IIc
Страница 1: ...CPE Installation and Pointing User Guide July 2013 Revision Number 1 1 Document Number DC 002966 D...
Страница 6: ......
Страница 12: ......
Страница 22: ......
Страница 68: ......
Страница 74: ......
Страница 84: ...82 CPE Installation and Pointing Proprietary and Confidential Figure 67 Mounting LNBF Adapter onto LNBF Bracket...