1.0 INTRODUCTION
This booklet describes the operating procedures for
-CP 40G-
series el/pump.
These pumps are usually used for marine application, to pump sea and fresh water, diesel oil, not
inflammables liquids and liquids without suspended parts. Most common uses are: bilge
discharge, diesel oil transfer, plant supply or where required a pump with a good flow rate.
The use of these machines must be made by qualified and experienced personnel, in full
compliance with local legislation.
These instructions should be carefully read before installation of any CP 40G series pump.
The Gianneschi Pumps and Blowers S.r.l. declines all responsibility in case of accident or
damage due to negligence or lack of observance of instructions given in this booklet, or
application in conditions not conforming to detail on the motor plate. All responsibility is
also declined for damage caused by improper use of the pump.
1.1 CONDITION OF USE
These el/pumps must be used with clean liquids in this condition:
- Max pressure admitted in the pump casing:
6 Bar
- Max suction depth:
8 Mt.
- Temperature of the liquid:
From -5°C to +60°C
- Max ambient temperature:
+50°C
- Voltage variation allowed:
± 5%
- Acoustic level:
<70 dB
- Starting:
Max 20/h
- Maximum viscosity:
Not suitable for viscous liquids
- Pumping abrasive liquids
Not suitable for abrasive liquids
- Pumping acid liquids
Min.PH=5
- Pumping alkaline liquids
Max.PH=8
1.2 HANDLING
The pump must
ALWAYS
be moved and transported in the horizontal position. Prior to moving the unit find
the following:
- total weight
- centre of gravity
- maximum outside dimensions
- lifting points location.
For a safe lifting it is recommended to use ropes, or belts properly positioned on the pump
and/or lifting eyebolts with correct movements, to prevent material damages and/or personal
injuries.
Lifting eyebolts fitted on single components of the assembly (pump or motor) should not be used
to lift the total assembly.
Avoid lifts whereby the ropes or straps, form a triangle with the top angle over 90°.
Prior to moving the unit from an installation, always drain any pumped fluid from the pump, piping and
accessories, rinse and plug all openings to prevent spillage.