![GHM GREISINGER GIA 20 EB Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/ghm/greisinger-gia-20-eb/greisinger-gia-20-eb_mounting-and-operating-manual_2220443031.webp)
E31.0.12.6C-06
Mounting and operating manual GIA 20 EB with electrically insulated supply
page 31 of 32
14. Specification
Absolute maximum ratings:
see chapter 5.2 (connection data)
Measuring input:
Standard inputs for
Input type
Signal
Range
Resolution
Note
Standard-
voltage-signal
0
– 10 V
0 ... 10 V
Ri > 300 kOhm
0
– 2 V
0 ... 2 V
Ri > 10 kOhm
0
– 1 V
0 ... 1 V
Ri > 10 kOhm
0
– 50 mV
0 ... 50 mV
Ri > 10 kOhm
Standard-
current-signal
4
– 20 mA
4 ... 20 mA
Ri = ~ 125 Ohm
0
– 20 mA
0 ... 20 mA
Ri = ~ 125 Ohm
RTD probes
Pt100
-50.0 ... +200.0 °C
( -58.0 ... +392.0 °F)
0.1 °C / °F
3-wire-connection
max. perm. line resistance: 20 Ohm
-200 ... +850 °C
( -328 ... +1562 °F)
1 °C /. °F
Pt1000
-200 ... +850 °C
(-328 ... +1562 °F)
1 °C /. °F
2- wire-connection
Thermocouple
probes
NiCr-Ni
(type K) -270 ... +1350 °C
(-454 ... +2462 °F)
1 °C / °F
Pt10Rh-Pt
(type S) -50 ... +1750 °C
(-58 ... +3182 °F)
1 °C /. °F
NiCrSi-NiSi
(type N) -270 ... +1300 °C
(-454 ... +2372 °F)
1 °C /. °F
Fe-CuNi (type J) -170 ... +950 °C
(-274 ... +1742 °F)
1 °C /. °F
Cu-CuNi (type T) -270 ... +400 °C
(-454 ... +752 °F)
1 °C /. °F
Frequency
TTL-Signal
0 Hz ... 10 kHz
0.1 mHz
Signal low: 0.0
– 0.5 V
Signal high: 2.7
– 24 V
Switching contact
NPN
0 Hz ... 3 kHz
0.1 mHz
i An internal pull-up-resistor (~11 kOhm
to +3.3V) is connected automatically.
Switching contact
PNP
0 Hz ... 1 kHz
0.1 mHz
An internal pull-down-resistor (~11 kOhm
to GND) is connected automatically.
Rotation
TTL-Signal,
Switching contact NPN,
PNP
0 ... 9999 U/min
0.001 U/min
Pre-scaling-factor (1-1000),
Pulse-frequency: max. 600000 p./min. *
Up/Down-
Counter
TTL-Signal,
Switching contact NPN,
PNP
0 ... 9999
with pre-scaling factor: 9 999 000
Pre-scaling-factor (1-1000)
Pulse-frequency: max. 10000 p./sec. *
Reset input
--
Reset:
R < 1 kOhm
Release:
R > 100 kOhm
* = with switching contact accordingly to frequency input lower values may occur
Display range:
(voltage-, current and frequency-measurement)
-1999 ... 9999 Digit, initial value, terminal value and decimal point position ar-
bitrary. Recommended range: < 2000 Digit
Accuracy::
(at nominal temperature)
Standard-signals:
< 0.2% FS ±1Digit (from 0
– 50mV: < 0.3% FS ±1Digit)
RTD:
< 0.5% FS ±1Digit
Thermocouples:
< 0.3% FS ±1Digit (from Type S: < 0.5% FS ±1Digit)