70
Status indicators
Gewiss
9. Status indicators
Depending on the operating modes available on the model purchased, the recharging station will have at least one tool for informing the
client about the status and the actions to be carried out.
9.1. RGB LED
The recharging station has 2 RGB LEDs, one for each side and socket-outlet. Their colour changes to inform the client about the status
of the station and the actions that need to be carried out. The colour change may be on one side only or on both, depending on the
situation.
Light
Description
Fixed green
The station is ready to start a charging session. No problem detected.
Flashing green
The station is waiting for the charging plug to be connected,
and the connection with the car
or
The charging station is waiting for the charging cable to be removed, d
isconnecting the car and ending the charging session.
Fixed blue
The charging session is in progress and the car is absorbing energy.
Flashing blue
The charging session is in progress, but the car is not absorbing energy
(charging terminated, or car not ready for recharging).
Fixed red
An internal error or a connection error with the car was detected by the station
and the charging process cannot be continued.
None
The station does not have the necessary electrical power supply.
9.2. Alphanumerical display
Each socket-outlet has a display showing various items of information that help the client understand the station status and the actions
required.
CHARGING PROCESS
Words on the display
Description
SWIPE THE CARD
TO RECHARGE
In RFID mode, the station waits for an RFID card, checks it is valid,
and then begins the recharging process.
CARD ENABLED
*PLEASE WAIT*
The RFID card has been recognised by the system.
*ATTENTION*
CARD NOT VALID
The RFID card has not been recognised, so the recharging session cannot be started.
CARD ENABLED
CONNECT THE CABLE
The station is waiting for the charging plug to be connected,
and the connection with the car.
RECHARGE IN PROGRESS
Ts=0000 Tc=0000
The session is in progress and the display shows the stationary time (Ts)
and the charging time (Tc).
RECHARGE IN PROGRESS
kW=00.00 kWh=00.00
The session is in progress and the display shows the power dispensed (kW)
and the energy absorbed by the car (kWh)
RECHARGE TERMINATED
REMOVE THE CABLE
The session has ended and the station is waiting for the cable to be removed.
SESSION SUMMARY
Ts=0000 Tc=0000
When the cable is removed, the station shows
a summary of the session that has just ended.
SESSION SUMMARY
kW=00.00 kWh=00.00
When the cable is removed, the station shows
a summary of the session that has just ended.
OUT OF SERVICE
DUE TO TECHNICAL PROBLEMS
There is an error that prevents starting or continuing
the charging session and therefore it will be ended.
LOCAL RFID CARD CONTROL
Words on the display
Description
*SAVING*
SWIPE THE CARDS
Once the MASTER card has been swiped, the station goes into acquisition mode. Swipe
one RFID card at a time so it can be read and added to the local White List.
7.55.4.515.2 - Installation and Operation Manual
Содержание JOINON
Страница 2: ......
Страница 3: ...Italiano IT English EN Français FR Español ES Deutsch DE Romanian RO Hungarian HU Nederlands NL ...
Страница 4: ...4 Gewiss 7 55 4 515 2 Manuale d installazione e uso ...
Страница 46: ...46 Gewiss 7 55 4 515 2 Installation and Operation Manual ...
Страница 88: ...88 Gewiss 7 55 4 515 2 Manuel d installation et usage ...
Страница 130: ...130 Gewiss 7 55 4 515 2 Manual de instalación y uso ...
Страница 172: ...172 Gewiss 7 55 4 515 2 Handbuch für Montage und Betrieb ...
Страница 214: ...214 Gewiss 7 55 4 515 2 Manual de instalare și utilizare ...
Страница 256: ...256 Gewiss 7 55 4 515 2 Használati és karbantartási kézikönyv ...
Страница 298: ...298 Gewiss 7 55 4 515 2 Installatie en gebruikshandleiding ...
Страница 340: ......