20
NRG 26-61 - Installation & Operating Manual -
819874-00
Technical data
Current input
■
■
Max. 0.3 A
Internal fuse
■
■
T2A
Safety cutout at excessive ambient temperature
■
■
The cutout at excessive ambient temperature takes place at T
amb.
= 75 °C
Input/output
■
■
Interface for CAN bus to ISO 11898, CANopen, insulated
■
■
M12 CAN bus connector, 5-pole, A-coded
■
■
M12 CAN bus socket, 5-pole, A-coded
Indicators and controls
■
■
1 x green 4-digit, 7-segment display for showing status information
■
■
1 x red LED for indicating an alarm
■
■
1 x green LED for indicating OK
■
■
1 x rotary knob IP65 with button for menu navigation and test function
Protection class
■
■
III Safety Extra Low Voltage (SELV)
IP rating to EN 60529
■
■
IP 65
Admissible ambient conditions
■
■
Service temperature:
0 °C – 70 °C
■
■
Storage temperature:
- 40 °C – 80 °C
■
■
Transport temperature:
- 40 °C – 80 °C
■
■
Air humidity:
10 % – 95 % non-condensing
Weight
■
■
Approx. 2.1 kg
Admissible installation positions
■
■
Vertical
■
■
Oblique to a maximum inclination of 45°. In this case, the length of the electrode rod is limited
to 688 mm maximum.