24
NOTE: The MSA processor
adjusts the fusion time
according to the external
temperature with temperature
compensated fittings.
Therefore, the final fusion
time values might be slightly different from the nominal values
captured from the barcode.
During the first 10-15 seconds of the fusion, the machine checks
the quality of the input voltage. If the input voltage is not adequate,
the fusion is interrupted and the following error message occurs.
NOTE: Check the voltage
stability and the power
capacity of the generator
before starting the fusion.
The operator can stop the
fusion process at any time by pushing STOP/ESC (O). Once
the STOP/ESC button has been pushed, the fusion process
immediately stops and an error message occurs (see ‘Error
Messages’ Section 5).
Stopping a fusion in progress will result in an incomplete
and potentially unreliable fusion: Ensuring a proper
fusion is the operator’s responsibility.
When the fusion cycle nears completion, an acoustic signal alerts
the user that the process is almost finished.
As soon as the fusion cycle
is complete, the display will
briefly show the information
concerning the fusion time and
the average current applied to