If the job number function is active and the user wants to bypass
this screen without entering any information, press the (
►)
button
and then the START/OK (I) button to proceed.
2.4 CONNECT FITTING
At this point, the display shows the ambient temperature, the
date/time, the voltage and frequency values of the input supply
voltage.
Attention: When the input
voltage is out of range (see
Technical Characteristics)
the display shows, in place of
the voltage value, ‘^^^’ if the
voltage is above the voltage
limit threshold, or ‘vvv’ if the voltage is below the voltage limit
threshold. In this case, the unit will stop the operation during
the fusion if the input voltage does not return within the voltage
threshold limit.
Attention: It is important to check that the fusion cable ends are
properly connected to the fitting’s terminal post before moving
forward.
Once the fusion cables have been connected to a fitting, push the
START/OK (I) button.
If a fitting is recognized, the processor program will advance
and the display message will change by asking for additional
information.
2.5 ENTER FUSION DATA
Fusion data can be entered by automatically reading the
implanted resistor in the fitting (CP mode), by reading the fitting’s
barcode label, or by inserting the fusion data manually. At this
stage, to ensure a reliable joining, pipes and fitting have to be