7.1 STANDARDS
• ISO 12176-2
• ISO 12176-3
• ISO 12176-4
• EN 60335-1 (Safety)
• EN 61000-6-2 (EMC)
• EN 61000-6-4 and others (EMC)
• CSA Certified
8. ENVIRONMENT CONDITIONS
8.1 WEATHER CONDITIONS
Cold weather affects both fittings and equipment. Electrofusion
fittings require the most energy at the beginning of the fusion
cycle. This energy requirement is increased in cold weather
situations. Make sure that your generator is in good mechanical
condition and that it meets the minimum wattage output.
8.2 POWER SOURCES
For the installation of electrofusion fittings in field applications, it
will be necessary to have a reliable source of AC power.
The selected AC power source should conform to the following:
• be well maintained and subjected to a periodic maintenance
schedule
• provide output voltage within the specified operating range of
the machine
• have a minimum wattage capacity per the fitting power table.
A matching outlet is needed to mate with the plug equipped on the
MSA electrofusion processor:
115V models —PLUG 30A/125V TWISTLOCK NEMA L5-30
230V models — PLUG 250V/30AMP TWISTLOCK NEMA L14-30