![Genie S-100 Скачать руководство пользователя страница 113](http://html.mh-extra.com/html/genie/s-100/s-100_service-and-repair-manual_2211877113.webp)
Part No. 1268494
S-100 • S-105 • S-120 • S-125
3 - 69
March 2017
Section 3 • Repair Procedures
LSB3RO:
Operational Limit Switch, 3’ Extend.
This switch activates anytime the boom is extend
-
ed beyond 3 feet. If axles are not extended, boom
extend is disabled and the extend axle LED and
icon will flash as long as boom extend is operat
-
ed. If axles are extended at this point, the motors
are shifted to low and drive speed is limited to
0.7 mph. The boom up/down speed and turntable
rotate speed are limited to 60% of maximum.
LSB3RS:
Safety Limit Switch, 3.5’ Extend. If axles
are not extended, this switch is activated when the
boom is extended beyond 3.5 feet, cutting power
to boom extend and axle retract.
LSB3EO:
Operational Limit Switch, 75’ Extend.
This switch activates anytime the boom is extend
-
ed to 75 feet or beyond. At this point drive speed is
reduced to 0.4 mph, boom up/down is reduced to
29% of maximum and turntable rotate is reduced
to 40% of maximum. If boom angle is less than
53
O
, then boom extend is disabled and the raise
boom LED and icon and alarm will flash as long as
boom extend is operated.
LSB4ES:
Safety Limit Switch, 75.5’ Extend. This
switch cuts power to boom extend, boom down
and engine fuel solenoid when it is mechanically
activated at 75.5 feet, if boom angle is less than
50
O
.
LSB4EO:
Operational Limit Switch, 100’ Extend.
This switch activates anytime the boom is extend
-
ed to 100 feet or beyond. The boom up/down is
reduced to 20% of maximum. If boom angle is less
than 68
O
, then boom extend is disabled and the
raise boom LED and icon and alarm will flash as
long as boom extend is operated. If boom angle is
greater than 65
O
, the BO lockout valve will activate
allowing hydraulic flow to the external cylinder to
continue to extend to 120 feet.
LIMIT SWITCHES
LSB6S:
Safety Limit Switch, Cable Tension. Cuts
power to the extend directional valve if extend
cables are out of adjustment or one breaks.
LSB1DO:
Operational Limit Switch, 10
O
Angle.
This switch activates anytime the boom is raised
above 10
O
. If axles are not extended, boom up is
disabled and the extend axle LED and icon will
flash as long as boom up is operated. At this point,
if axles are extended, the motors are shifted to low
and drive speed is limited to 0.7 mph.
LSB7DS:
Safety Limit Switch, 11
O
Angle. If axles
are not extended, this switch is activated when
boom is raised to 11
O
, cutting power to boom up
and axle retract.
LSB13AO:
Operational Limit Switch, 53
O
Angle.
This switch activates at 53
O
boom angle, allowing
the boom to be extended beyond 75 feet. If the
boom is lowered past this switch when the boom
is beyond 75 feet, boom extend and boom down
are disabled. The retract boom LED and icon and
alarm will flash as long as boom down is operated.
LSB8AS:
Safety Limit Switch, 50
O
Angle. This
switch cuts power to boom extend, boom down
and the engine fuel solenoid when it is mechan-
ically activated at 50
O
if the boom length is more
than 75.5 feet.
LSB14AO:
Operational Limit Switch, 68
O
Angle.
This switch is activated at 68
O
boom angle and al-
lows the boom to be extended beyond 100 feet. If
the boom is lowered past this switch when extend
-
ed beyond 100 feet, boom extend and boom down
are disabled. The boom retract LED and icon and
alarm will flash as long as boom down is operated.
LSB9AS:
Safety Limit Switch, 65
O
Angle. This
switch cuts power to boom extend, boom down
and the engine fuel solenoid when it is mechan-
ically activated at 65
O
if the boom length is more
than 101 feet.
Содержание S-100
Страница 224: ...4 38 S 100 S 105 S 120 S 125 Part No 1268494 March 2017 Section 4 Diagnostic Codes This page intentionally left blank ...
Страница 244: ...March 2017 Section 5 Schematics 5 20 S 100 S 105 S 120 S 125 Part No 1268494 This page intentionally left blank ...
Страница 246: ...March 2017 Section 6 Schematics 6 22 Safety Circuit Schematic 6 21 ...
Страница 253: ...Section 6 Schematics March 2017 6 29 Engine Options Perkins S 100 105 120 125 from serial number 874 6 30 ...
Страница 259: ...Section 6 Schematics March 2017 6 35 6 36 Electrical Schematic Generator Options ...
Страница 262: ...March 2017 Section 6 Schematics 6 38 6 37 Electrical Schematic 12 kW Generator welder option ...
Страница 264: ...March 2017 Section 6 Schematics 6 40 Perkins 1104D 44T Engine Electrical Schematic 6 39 ...
Страница 265: ...Section 6 Schematics March 2017 6 41 Perkins 854F 34T Engine Electrical Schematic 6 42 ...
Страница 267: ...Part No 1268494 S 100 S 105 S 120 S 125 6 43 March 2017 Section 6 Schematics Perkins 854F 34T Engine Electrical Harness ...
Страница 268: ...March 2017 Section 6 Schematics 6 44 Perkins 854F 34T Engine Harness 6 45 ...
Страница 269: ...Section 6 Schematics March 2017 6 45 Deutz TD2011L04i Engine Electrical Schematic 6 46 ...
Страница 271: ...Section 6 Schematics March 2017 6 47 Deutz TD2 9 Engine Electrical Schematic 6 48 ...
Страница 272: ...6 48 S 100 S 105 S 120 S 125 Part No 1268494 March 2017 Section 6 Schematics Deutz TD2 9 Engine Electrical Schematic ...
Страница 273: ...Part No 1268494 S 100 S 105 S 120 S 125 6 49 March 2017 Section 6 Schematics Deutz TD2 9 Engine Electrical Harness ...
Страница 274: ...March 2017 Section 6 Schematics 6 50 Deutz TD2 9 Engine Electrical Harness 6 51 ...
Страница 276: ...March 2017 Section 6 Schematics 6 52 6 53 Hydraulic Schematic 12 kW Generator welder option ...
Страница 277: ...Section 6 Schematics March 2017 6 53 Hydraulic Schematic S 100 S 105 Models serial number 136 6 54 ...
Страница 284: ...March 2017 Section 6 Schematics 6 60 Hydraulic Schematic S 100 S 105 Models from serial number 739 6 61 ...
Страница 293: ...Section 6 Schematics March 2017 6 69 Hydraulic Schematic S 120 S 125 Models from serial number 3146 to S12514D 921 6 70 ...
Страница 296: ...March 2017 Section 6 Schematics 6 72 Hydraulic Schematic S 120 S 125 Models from serial number S12514D 922 6 73 ...