Geniewatch, NSD5451 User Manual (Ver. 1.0)
Genie Network
35
Alarm Input Setup
ALARM INPUT SETUP
------------------------
ALARM NO. 1
TYPE N.OPEN
ACTION NOT USED
HOLD TIME ENDLESS
POST ACTION HOME
BACK
EXIT
Sets alarm function.
z
Alarm No
[1~4]
Selects a sensor number to set up.
z
Type
[Normal OPEN/Normal CLOSE]
Sets sensor operation type.
z
Action
[NOT
USED/PRESET/PATTERN/SWING/GROUP]
Sets actions to run when sensor is input.
z
Hold Time
[ENDLESS/1~59 sec/1~180 minute]
Sets the time period for the action which
is run by external sensor activation. After
the time period passes, the action pre-
defined in “Post Action” runs sequentially
in succession to the action by external
sensor activation. If this option is set to
“ENDLESS”, “Post Action” does not
activate.
z
Post Action
[HOME/PRESET/PATTERN/SWING/GROUP/
PREV ACTION]
Sets the action that a camera should run
after the time period in“HOLD TIME”
passes