Geniewatch, NSD5451 User Manual (Ver. 1.0)
Genie Network
13
Communication Protocol Setup
Select the appropriate Protocol with DIP switch
combination.
1
2
3
4
ON
ON
Switch State
P0
(Pin 1)
P1
(Pin 2)
Protocol
OFF
OFF
PELCO-D, 2400 bps
ON
OFF
PELCO-D, 9600 bps
OFF
ON
PELCO-P, 4800 bps
ON
ON
PELCO-P, 9600 bps
If you want to control using DVR or P/T controller, their
protocol must be identical to camera. Otherwise, you can
not control the camera.
If you changed camera protocol by changing DIP S/W,
the change will be effective after you reboot the camera.
Factory default of protocol is “Pelco-D, 2400 bps”.
NTSC/PAL (Reserved for Supplier)
z
Since Pin 3 is only for supplier, DO NOT CHANGE THESE
ITS ORIGINAL STATE. If you change one of these, proper
operation can not be achieved.
~
Pin 3
1
2
3
4
ON
ON
PAL / NTSC system selection of Camera. DO
NOT CHANGE THIS PIN.