Sec-5.1
Section 5: Troubleshooting
The GCL-MT operators include a self-diagnostic circuit board using troubleshooting LED indicators to signal
the technician of a problem.
TROUBLESHOOTING LED’s
HOIST
INTERLOCK
EXTERNAL
INTERLOCK
+24VDC
STB
ENABLE
INDICATION
OFF
STB Disabled
ON
STB Enabled
ON
ON
ON
Normal Operating Condition
OFF
ON
ON
Hoist Interlock Switch Open:
• Hoist release requires reset
• Hoist interlock connector not plugged in
• Hoist interlock defective
OFF
OFF
ON
External Interlock Open
OFF
OFF
OFF
Power Supply Problem:
• Check AC power supply
• Check main power fuse
• Check secondary fuse (2A)