Sec-2.8
Section 2: Operator Installation
1. Raise the operator and position it so that the drawbar tracks are level and perpendicular to the face of
the door (or the stile where the door bracket will be attached). FIG. 9.
2. Lock the drawbar tracks into the spreader bracket using two 1 /4”-20 x 9/16” track bolts & two lock nuts.
NOTE:
Track bolts MUST be installed from inside the track.
3. Secure the operator in position by installing steel angles (not provided) between the ceiling
superstructure and the operator. FIG. 10.
TRACK BOLTS
& LOCK NUTS
ROPE, CABLE,
CHAIN, ETC.
LEVEL
WALL
WALL
TRACK
90°
DOOR FROM ABOVE
FIG. 9
FIG. 10
INSTALL CARRIAGE BOLTS
UNDER PLATE
COMPLETED
ASSEMBLY