Sec-4.13
1. Press CAL/RUN to enter CALIBRATION MODE.
2. Press SCROLL until display reads GDO V# > #####. FIG. 8.
• This display will cycle between the version number of the current GDO firmware and the current
display firmware.
3. Press CAL/RUN to return to RUN mode.
GDO and Display Firmware
OPEN
CLOSE
STOP
CAL
RUN
SCROLL
SCROLL
SET
CLEAR
DISPLAY V# ####
OPEN
CLOSE
STOP
CAL
RUN
SCROLL
SCROLL
SET
CLEAR
GDO V# ######
1. Press CAL/RUN to enter CALIBRATION MODE.
2. Press SCROLL until display reads GDO TYPE >. FIG. 9.
• This will display the current GDO type.
3. Press SET/CLEAR until display indicates correct GDO TYPE.
4. Press CAL/RUN to return to RUN mode.
GDO Type
OPEN
CLOSE
STOP
CAL
RUN
SCROLL
SCROLL
SET
CLEAR
GDO TYPE TROLLEY
This operator is available for use in trolley configuration only. However, the same control board is used for
jackshaft and trolley models. Service replacement boards need to have GDO TYPE set for the appropriate
model configuration.
NOTE:
The GDO type is factory set. The installer should not have to set this feature. However, if the GDO type is
inadvertently changed, or if a board needs to be replaced in the field, follow these instructions to set GDO type.
FIG. 8
FIG. 9
Section 4: Programming