Sec-3.12
Monitored Edges, Wireless
1. Mount Wireless Edge Receiver adjacent to operator.
2. Route MEL wireless receiver wires into operator electric box using suitable conduit and clamp systems.
3. Attach MEL wireless receiver power wires (blue/yellow) to external radio plug as shown below.
4. Attach MEL wireless receiver trip wires (white/white) to ODC STB terminals on control wire terminal
strip.
5. Mount MEL wireless transmitter to bottom edge of door per MEL instructions.
Right-hand installation shown, Left-hand installation mirrored
Actuating the operator by using constant contact on the CLOSE button will override non-functioning
external reversing devices, including sensing edges.
WARNING
!
AVERTISSEMENT
!
L’activation de l’operateur en util isant un contact constant sur le bouton FERMER annulera les dispositifs
d’inversions externes, y compris les systèmes de détection des bords.
MillerEdge® Wireless Monitored Sensing Edge Installation
Section 3: Wiring
NOTE:
Installer must enable ODC STB in CALIBRATION MODE (see programming section)
External Radio Harness
Blue
Yellow
Orange
Control Wire
Terminals
ODC
STB
ODC
STB
Yellow
Blue
MEL-II
Power
MEL-II-8 pin connector
CH 1 CH2
CO
M
PULSED
MEL-II
Transmitter
PWR
W
hit
e
W
hit
e
OPERATOR
TERMINAL
STRIP
MEL-II
RECEIVER
Содержание GCL-MT
Страница 36: ...Sec 4 5 THIS PAGE INTENTIONALLY BLANK...
Страница 58: ......
Страница 60: ...The Genie Company 1 Door Drive Mount Hope OH 44660 1 800 843 4084 www geniecompany com...