Sec-4.2
Section 4: Programming
If at any time should programming become confused. Press the CAL/RUN key once to enter RUN MODE then press
CAL/RUN key again to re-enter CALIBRATION MODE.
Press the SCROLL key(s) to locate or check the settings on any menu item.
Calibration Mode Structure
OPEN
CLOSE
STOP
CAL
RUN
SCROLL
SCROLL
SET
CLEAR
RUN MODE
• MAX RUN TMR (MRT) will set itself once limits have been programmed and door has run one complete
cycle.
• RUN and ERROR codes will retain the last 10 codes encountered. Press the SET/CLEAR key to toggle
through all codes.
NOTE:
Menu structure will change when any auxiliary board(s) are added. See instructions for each auxiliary
board for changes.
OPEN
CLOSE
STOP
CAL
RUN
SCROLL
SCROLL
SET
CLEAR
CALIBRATION MODE
Operator Calibration Menu Structure
1. Open Mode
2. Close Mode
3. Down Limit Overrun
4. ODC STB
5. Mid-Stop
6. Max Run Timer
7. Learn New Transmitter
8. Clear One Transmitter
9. Clear All Transmitters
10. Error Code
11. Run Code
12. Cycles
13. GDO Version #
14. GDO Type
15. Set Close Direction
16. Set Up Limit
17. Set Down Limit
When entering CALIBRATION MODE the menu will always start at OPEN MODE >XXX. Press SCROLL key to bypass
this item until desired menu item is displayed.