![Genie GCL-J&H Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/genie/gcl-jandh/gcl-jandh_installation-manual_2212172039.webp)
8.5
Monitored Photocell Self-diagnostic Troubleshooting Chart
ON
ON
NORMAL OPERATION
NONE REQUIRED
OFF
OFF
1. POWER HEAD NOT POWERED
2. WIRING FROM POWER HEAD BAD
1. CHECK BREAKERS, FUSES, PLUGS
2. CHECK WIRING FOR OBVIOUS SHORTS
OFF
ON
1. WIRING TO SOURCE MISSING OR BAD
2. POWER HAS BEEN INTERRUPTED
1. CHECK WIRING
2. REMOVE POWER AND REAPPLY
2 BLINKS, PAUSE
(REPEAT)
ON
1. BEAM NOT ALIGNED
2. BEAM OBSTRUCTED
3. SENSOR DEFECTIVE
1.CHECK ALIGNMENT
2. CHECK FOR OBSTRUCTION
3. CALL CUSTOMER SERVICE
1. WIRE TO SENSOR MISSING OR BAD
2. SENSOR DEFECTIVE
1. CHECK WIRING
2. CALL CUSTOMER SERVICE
OFF
ON
1. SENSOR RECEIVING INTERFERENCE 1. ATTEMPT TO DETERMINE SOURCE OF
INTERFERENCE
2. CALL CUSTOMER SERVICE
ON
1. SOURCE NOT SENDING PULSES
2. SOURCE DEFECTIVE
1. CALL CUSTOMER SERVICE
2. CALL CUSTOMER SERVICE
SOURCE (RED LED) SENSOR (GREEN LED)
INDICATED CONDITION
REQUIRED ACTION
2 BLINKS, PAUSE
(REPEAT)
3 BLINKS, PAUSE
(REPEAT)
4 BLINKS, PAUSE
(REPEAT)
WARNING:
Actuating the operator by using constant contact
on the CLOSE button will override all reversing devices.
WARNING
: The Corporation recommends that
line voltage wiring be performed by a qualified electrician.
See Section 5 for additional wiring instructions.
www.geniecompany.com
0
-12
Standard Duty Operator
GCL-J&H