7.2
OPEN
CLOSE
STOP
CAL
RUN
SCROLL
SCROLL
SET
CLEAR
GDO TYPE J-SHAFT
Figure 3
Operator Type Fig. 3
CAL
RUN
CAL
RUN
SCROLL
SET
CLEAR
NOTE
: The GDO type is factory set. The installer should not have to set this
feature. However, if the GDO type is inadvertently changed, or if a board needs
to be replaced in the field, follow these instructions to set GDO type.
1) Press CAL/RUN key to enter calibration mode.
2) Press SCROLL key until display reads “GDO TYPE
>
.”
Figure 3
.
This will display the current GDO type.
3) Press SET/CLEAR key until display indicates correct GDO type
( J-SHAFT or TROLLEY)
4) Press CAL/RUN key to return to run mode.
www.geniecompany.com