![Genie GCL-J&H Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/genie/gcl-jandh/gcl-jandh_installation-manual_2212172031.webp)
6.8
CLOSE
STOP
CAL
SET
LEARN NEW XMTR?
Adding a Transmitter
1) If operator is in RUN mode, press CAL/RUN key to enter calibration mode.
2) Press SCROLL key (up or down) until display reads “LEARN NEW XMTR? ”
Figure 13
.
This question along with the instruction “HIT SET FOR YES” will
continuously pan across the display window. (Pressing SCROLL or
CAL/RUN will cancel the operation.)
3) Press SET/CLEAR key.
Display will read “PUSH XMTR BUTTON TWO TIMES TO LEARN XMTR.”
4) Press Transmitter button two times.
The display will read “XMTR ___LEARNED.” Where it assigns a random
number between 1 and 50 to the transmitter. That transmitter is
entered and ready to operate the door. (Label/mark the transmitter.)
5) Press SCROLL key (up or down) to move on to another menu item,
or CAL/RUN key to exit the CAL mode.
(Optional) Transmitter Programming
LO
CAL
RUN
C
SCROL
C
SE
CL AR
SET
CLEAR
SCROLL
CAL
RUN
Removing Individual Transmitter
1) If operator is in RUN mode, press CAL/RUN key to enter calibration mode.
2) Press SCROLL key (up or down) until display reads “REMOVE XMTR? ”
Figure 14
This question along with the instruction “HIT SET FOR YES” will
continuously pan across the display window. (Pressing SCROLL or
CAL/RUN will cancel the operation.)
A menu displaying the available transmitter numbers will appear.
Press SCROLL key (up or down) to cycle through the menu to the
number of the transmitter to be removed. (Pressing CAL/RUN will
cancel the operation.)
The transmitter is removed.
5) Press SCROLL key (up or down) to move on to another menu item,
or CAL/RUN key to exit the CAL mode.
L E
CAL
RUN
C L
SCROLL
SCROLL
CAL
RUN
CLOSE
STOP
CAL
SET
REMOVE XMTR?
Figure 14
Removing All Transmitters
1) If operator is in RUN mode, press CAL/RUN key to enter calibration mode.
2) Press SCROLL key (up or down) until display reads “REMOVE ALL XMTRS”
Figure 15
.
This question along with the instruction “HIT SET FOR YES” will
continuously pan across the display window. (Pressing SCROLL or
CAL/RUN will cancel the operation.)
3) Press the SET/CLEAR key.
The display will read “ARE YOU SURE.”
All transmitters are removed.
5) Press SCROLL key (up or down) to move on to another menu item,
or CAL/RUN key to exit the cal mode.
CAL
RUN
CROLL
S O L
SET
CLEAR
4) Press the SET/CLEAR
key.
SET
CLEAR
SCROLL
CAL
RUN
CLOSE
STOP
CAL
SET
REMOVE ALL XMTRS?
Figure 15
SCROLL
3) Press SET/CLEAR key.
SET
CLEAR
4) Press SET/CLEAR key.
SET
CLEA
Figure 13
www.geniecompany.com
0
-12
Standard Duty Operator
GCL-J&H