Operators also include a run code memory that stores the last 10 run events.
These codes are stored with or without power. Each time the operator runs or stops, it
generates a code that it stores in this memory (Why the operator ran or stopped). Used
together with the error code memory, it becomes a powerful troubleshooting aid.
The run code memory stores the last 10 codes in sequence. Once 10 codes are stored,
the oldest code is erased to make room for the newest code. These codes are displayed
in calibration mode. The display will flash the number of the run code and the 2-digit
run code followed by a description of the run code.
Fig. 3 & 4
.
Run Codes
RUN CODE 1 3C
Figure 3
HALT DOWN LIMIT
Figure 4
Error Codes
(continued)
CAL
RUN
L
SCROLL
C
SET
CLEAR
CAL
RUN
To view the error code memory
:
1) Press CAL/RUN key to enter calibration mode.
2) Press SCROLL key until display reads “ERROR CODE 1
>
”.
•
The display will begin flashing the error code number and 2-digit
error code followed by its description.
•
Reminder: Error code number 1 is the latest code generated.
3) Press SET/CLEAR key. The display will now read “ERROR CODE 2
>
.”
(This is the error code which was generated before error code 1.)
4) Repeat step 3 until all 10 error codes have been displayed or move on to
step 5 when ready.
5) Press CAL/RUN key to return to run mode.
NOTE
: For all error codes see Appendix C, Pages 10.11 - 10.12.