Genie Raptor Manual Ver. 3.1
24
Edition. GN-April-2013
• MD DEFINE
When DEFINE is ON, MD is activated.
• MD DISPLAY
If MD DISPLAY is set to ON, “MOTION” appears on the bottom right hand side of the screen.
Motion Detection doesn’t work when the OSD MENU is activated.
• SENSITIVITY
The Motion Detection sensitivity level is adjustable.
As the sensitivity level increases the possibility of false activations also increases.
• INTERVAL T
MD is re-activated, according to the set time, after motion has been detected.
• AREA START H, AREA START V
Set a start area for Motion Detection.
• AREA END H, AREA END V
Set an end area for Motion Detection.
Caution
1.
Motion Detection doesn’t work in SCAN & PATTERN settings.
2.
When using MD, the DWELL TIME should be a minimum of 3 seconds in TOUR settings.
3.
Do not set MD if an unstable light source is present e.g. flickering light.
4.
Instant changes in light sources may cause false activations e.g. turning lights on or off.
5.
This MD function is not intended for fire or antitheft protection and the manufacturer frees
itself from any responsibility should it malfunction.
2.2 MOTION DETECTION
1. MD DEFINE OFF / ON
2. MD DISPLAY OFF / ON
3. SENSITIVITY 1~25
4. INTERVAL T 1 SEC ~ 4 MINUTES
5. AREA START H 0~XX
6. AREA START V 0~XX
7. AREA END H XX~12
8. AREA END V XX~8
9. EXIT