Genie Raptor Manual Ver. 3.1
12
Edition. GN-April-2013
• Protocol Settings
Protocol is selected using switches DP21-1, DP21-2, DP21-3 and DP21-4.
The configuration of the Protocol is as follows.
When an installer uses a protocol based Coaxial cable, it isn’t using a RS485 Address so you
can leave the Address as 0
• Baud Rate Settings
The Baud Rate, communication speed, is selected using switches DP21-5, DP21-6 and DP21-7.
Baud Rate configuration settings are as follows:
Description
No
DP21-1
DP21-2
DP21-3
DP21-4
Apply
PELCO-D
0
OFF
OFF
OFF
OFF
OK
PELCO-P
1
ON
OFF
OFF
OFF
OK
BBV
2
OFF
ON
OFF
OFF
OK
VCL
3
ON
ON
OFF
OFF
OK
PANASONIC
4
OFF
OFF
ON
OFF
OK
AD
5
ON
OFF
ON
OFF
OK
HONEYWELL
6
OFF
ON
ON
OFF
OK
SAMSUNG
7
ON
ON
ON
OFF
OK
FVISION
8
OFF
OFF
OFF
ON
OK