37
Genie Raptor Manual Ver. 3.1
Edition. GN-April-2013
3.3 SCAN
This function automatically moves the camera back and forth from one point to another.
1. SCAN NO 1 ~ 5
2. SCAN DEFINE OFF / ON
3. NAME SCANGROUP1
4. SCAN NAME DEF OFF / ON
5. PANSTART POS 180
6. PAN END POS 350
7. TILT POS 45
8. SCAN SPEED 2°, 5°, 10°, 20° /SECOND
9. EXIT
•
SCAN NO
A maximum of 5 Scans can be registered.
•
SCAN NO DEF
OFF: SCAN is cancelled
ON:
SCAN can be set up (it should be ON for operation in AUTO RUN) Setting Example
SCAN will be executed in programmed preset 1, 3 & 5.
The method for setting up SCAN1 in PRESET is as follows:
1. Register “1” as the SCAN NO.
2. Change SCAN DEFINE from OFF to ON and press the IRIS OPEN KEY.
•
NAME
This changes the SCAN Name.
The method for changing the SCAN NAME is as follows:
1. Change SCAN NAME DEF from OFF to ON and press the IRIS OPEN KEY.
2. The method for changing the SCAN name is the same as for “1.3 CAMERA NAME
•
PAN START POS
This sets up the initial location for the SCAN.
The method for setting up a SCAN is as follows:
1. Press the IRIS OPEN KEY in PAN START POS.
SCAN NO
1
2
3
4
5
SCAN DEF
ON
OFF
ON
OFF
ON
Содержание Raptor II Ruggedized PTZ
Страница 46: ......