ADV200 SP • Quick start up guide - Specification and installation
73
9.6 Output electrical data
U2 Max output voltage �������������������������� 0,94 x U
ln
(U
ln
=AC Input voltage)
f2 Max output frequency ������������������������ 500 Hz (Sizes 1015 ... 61600)
see section 9.3.3 for more details.
Braking IGBT Unit ����������������������������� KBX models: standard internal with external resistor,
KXX: not included;
braking torque 150 % MAX
Maximum voltage imbalance
�������������������� 400Vrms, 565
V
pk
Note!
In the event of insulation loss, the drive must be immediately disabled and disconnected from power sources..
Sizes
Inverter Output
P
n
mot (Recommended asynchronous motor output)
Heavy duty
(kVA)
Light duty
(kVA)
Heavy duty
Light duty
@400
V
ac
(kW)
@460
V
ac
(Hp)
@400
V
ac
(kW)
@460
V
ac
(Hp)
1015
1.7
3.0
0.75
1
1.5
2
1022
3.0
4.0
1.5
2
2.2
3
1030
4.0
5.3
2.2
3
3
5
1040
5.3
6.6
3.0
5
4
5
1055
6.6
9
4.0
5
5.5
7.5
2075
9
11.4
5.5
7.5
7.5
10
2110
11.4
15.9
7.5
10
11
15
2150
15.9
21.5
11
15
15
20
3185
21.5
26.3
15
20
18.5
25
3220
26.3
32
18.5
25
22
30
3300
32
43
22
30
30
40
4370
43
52
30
40
37
50
4450
52
60
37
50
45
60
4550
60
73
45
60
55
75
5750
73
104
55
75
75
100
5900
104
125
75
100
90
125
51100
125
145
90
125
110
150
61320
145
173
110
150
132
175
61600
173
208
132
175
160
200
Sizes
I
n
Rated output current
(For Asynchronous motors)
@U
ln
=40
0V
ac
@U
ln
=46
0V
ac
Heavy duty
(A)
Light duty
(A)
Heavy duty
(A)
Light duty
(A)
1015
2.5
4.3
2.3
3.9
1022
4.3
5.8
3.9
5.2
1030
5.8
7.6
5.2
6.8
1040
7.6
9.5
6.8
8.6
1055
9.5
13
8,6
11.7
2075
13
16.5
11.7
14.9
2110
16.5
23
14.9
20.7
2150
23
31
20.7
27.9
3185
31
38
27.9
34.2
3220
38
46
34.2
41.4
3300
46
62
41.4
55.8
4370
62
75
55.8
67.5
4450
75
87
67.5
78.3
4550
87
105