ADV200-HC Manual
Page 8 of 55
4
DESCRIPTION OF FUNCTIONS AND LIST OF PARAMETERS
26.01 MONITOR
The monitor parameters let you identify the operating state of the drive and of user-enabled functions.
States 1 and 2 indicate if the motor is running (RUN), driven by the drive and with handbrake open, or if the
motor is stopped with the handbrake closed (STOP).
States 3-4-6-9-10 indicate that the corresponding function has been activated (if conditions allow and if the
function is enabled) and is acting on the drive setting.
State 7 indicates that an alarm has tripped.
State 8 indicates that a limit switch contact has tripped: the user can handle the load only in the direction
opposite the limit switch until the tripped contact returns to normal position.
MENU
PAR
Description
UM
Type
Def
Min
Max
ACCESS
26.01.01
12000
Drive state mon
*
ENUM *
*
*
R
1 STOP Brake closed, drive disabled..
2 pre RUN Wait to exceed min. time for brake release.
3 RUN Brake open, drive enabled.
4 ALARM Active alarm.
5 Limit switch Limit switch tripped.
6 RUN cmd Ctrl COMMAND CONTROL function ON
7 RUN spd up HOIST SPEED UP function ON.
8 RUN pwr up SPEED UP function ON.
9 RUN low speed LOW SPEED ZONE function ON.
10 RUN anti sway ANTI SWAY function ON.
11 RUN antiImpact ANTI IMPACT function ON.
12 RUN align ALIGNEMENT function ON.
26.01.02
12002
Movement type mon
*
ENUM *
*
*
R
Displays type of movement and drive configuration.
Stand Alone
Electric Shaft
Master Follower
0
1
2
Hoist
Gantry
Trolley
3
4
5
Hoist-ELS-VM
Gantry-ELS-VM
Trolley-ELS-VM
9
10
11
Hoist-HL-M
Gantry-HL-M
Trolley-HL-M
6
7
8
Hoist-ELS
Gantry-ELS
Trolley-ELS
12
13
14
Hoist-HL-S
Gantry-HL-S
Trolley-HL-S
26.01.03
12004
Anti Sway mon
*
BOOL *
*
*
R
Monitor activation anti-sway function.
26.01.04
12006
Brake FWD cur mon
*
BOOL *
*
*
R
Monitor current limit exceeded for brake opening, FWD.
26.01.05
12008
Brake FWD trq mon
*
BOOL *
*
*
R
Monitor torque limit exceeded for brake opening, FWD.
26.01.06
12010
Brake FWD spd mon
*
BOOL *
*
*
R
Monitor speed limit exceeded for brake opening, FWD.
26.01.07
12012
Brake REV cur mon
*
BOOL *
*
*
R
Monitor current limit exceeded for brake opening, REV
Содержание ADV200 ASY