26.13 DIGITAL INPUTS
This menu lets you set the digital inputs.
MENU
PAR
Description
UM
Type
Def
Min
Max
ACCESS
26.13.01
11152
FWD cmd src
*
ENUM
Dig inp1
*
*
R/W
Digital input for Forward command.
26. 13.02 11154
REV cmd src
*
ENUM
Dig inp2
*
*
R/W
Digital input for Reverse command.
26. 13.03 11156
Multi spd 1 src
*
ENUM
Dig inp3
*
*
R/W
Digital input for multispeed 1 command.
26. 13.04 11158
Multi spd 2 src
*
ENUM
Dig inp4
*
*
R/W
Digital input for multispeed 2 command.
26. 13.05 11160
Jstk Zero pos src
*
ENUM
Dig inp5
*
*
R/W
Digital input for joystick ZERO position.
26. 13.06 11162
Anti Impact src
*
ENUM
Dig inp1X
*
*
R/W
Digital input to activate Anti Impact.
26. 13.07 11164
Limit switch src
*
ENUM
Dig inp2X
*
*
R/W
Digital input for limit switch contacts.
26. 13.08 11166
Brake fbk src
*
ENUM
Dig inp3X
*
*
R/W
Digital input for brake feedback.
26. 13.09 11168
ELS src
*
ENUM
Dig inp4X
*
*
R/W
Digital input to activate following.
Input to be set only on drives configured as …-ELS-VM, …-ELS.
26. 13.10 11180
Reset src
*
ENUM
Dig inp5X
*
*
R/W
Digital input for Reset alarms command.
26. 13.11 11194
Anti sway src
*
ENUM
Dig inp6X
*
*
R/W
Digital input to activate Anti Sway.
26. 13.12 11196
ELS align src
*
ENUM
Dig inp7X
*
*
R/W
Digital input to activate alignment of drives in Electric Shaft.
Input to be set only on drives configured as …-ELS-VM, …-ELS.
Parameters source “src” can be assigned to any digital input.
If the source is used to enable a function, for example Anti Sway, you can set the value of Anti sway src =
One. In this case, the function is always active.