ADV200-HC Manual
Page 14 of 55
If the “ZERO CROSSING” function is enabled, the reversal of direction is blocked without closing of the
brake; when a command in the opposite direction is received during movement, if the “ZERO CROSSING”
function is enabled the close brake sequence is activated, the brake remains closed for a time equal to “Zero
Crossing delay,” after which the brake is opened and the new command is executed.
MENU
PAR
Description
UM
Type
Def
Min
Max
ACCESS
26.03.01
11012
FWD cmd keeping
ms
FLOAT 0
0
5000 R/W
Command keeping time in FWD direction.
26.03.02
11014
REV cmd keeping
ms
FLOAT 0
0
5000 R/W
Command keeping time in REV direction.
26.03.03
11034
Min time cmd jstk
ms
FLOAT 10
0
1000 R/W
Minimum keeping time of a command, beyond which the command is executed.
26.03.04
11100
Zero crossing
*
BOOL Off
*
*
R/W
Enabling of Zero Crossing function.
26.03.05
11110
Zero crossing delay
ms
FLOAT 200
0
5000 R/W
Delay for restart after brake close for reversal of direction.
The “ZERO CROSSING” function cannot be enabled on drives configured as ..-ELS-M, …ELS
Содержание ADV200 ASY