26.15 ANALOG INPUTS
This menu contains the analog input settings.
MENU
PAR
Description
UM
Type
Def
Min
Max
ACCESS
26.15.01
11104
Speed ref src
*
ENUM
Analog
inp 1
*
*
R/W
Analog input for setting speed reference.
26.16 ALARM CONFIG
This menu contains the application alarm settings.
The action of an alarm depends on how its “Action” parameter was set:
Signal
Reset Condition
Drive
Brake
Warning
Alarm
None
Normal operation
Normal operation
Warning
X
Automatic, when fault
condition is eliminated
Normal operation
Normal operation
Alarm
X
Manual
Disabled
Closed
MENU
PAR
Description
UM
Type
Def
Min
Max
ACCESS
26. 16.01 11022
Brake fbk time
ms FLOAT 400
0
10000 R/W
Maximum time allowed from sending of brake command to reception of brake feedback.
If, after the set time, the FW detects that the feedback state does not match the command, the
action provided in “BRAKE FBK action” is activated.
26. 16.02 11066
Brake fbk action
*
ENUM Alarm *
*
R/W
Action to be taken if brake feedback does not match command within time set in “Brake fbk
time”..
26. 16.03
11086
Jstk time
ms FLOAT 400
0
10000
R/W
Maximum allowed time for reception of multiple commands from joystick.
If, after the set time, the software detects multiple commands (ex: FWD + REV) the action
provided in “Jstk action” is activated.
26. 16.04
11088
Jstk action
*
ENUM Alarm *
*
R/W
Action to be taken if software detects multiple commands for a time exceeding “Jstk time”.
26. 16.05
11090
AI time
ms FLOAT 500
0
10000
R/W
Maximum allowed time after which, if torque ( drive in FOC CL and FOC OL mode) or current
(drive in V/f mode) exceeds the impact threshold set in “AI Thr,” the action provided in “AI
action” is activated.
26. 16.06
11098
AI action
*
ENUM Alarm *
*
R/W
Action to be taken if software detects that torque (current) exceeds the impact threshold for a
time set in “AI time”.
26. 16.07 11126
OL1 time
ms FLOAT 100
0
10000 R/W
Maximum allowed time after which, if torque (in FOC CL and FOC OL mode) or current (in V/f
mode) exceeds the Overload threshold set in “OL1 Load thr,” the action provided in “OL1
action” is activated