ADV200-HC Manual
Page 30 of 55
MENU
PAR
Description
UM
Type
Def
Min
Max
ACCESS
26.10.01
11016
Enable Anti Impact
*
ENUM Off
*
*
R/W
On = ANTIIMPACT function ready to be activated.
The function will be activated by the command on the related digital input (DIGITAL INPUTS
menu \ Antimpact src = Dig inp ...)
26.10.02
11018
AI speed
Rpm FLOAT 200
0
6000 R/W
Speed reference set when function activation command is received from operator.
26.10.03
11020
AI Thr
%
FLOAT 50
0
200
R/W
Impact is identified when, during a movement, current or torque increases instantaneously by
a percentage equal to or greater than this parameter.
In V/f mode, the parameter is a % of nominal current of the motor.
In FOC CL or FOC OL mode, the AI Thr parameter is a % of nominal torque of the motor.
-
The Anti Impact function must be available to the operator when needed. Therefore, an On/Off
switch will be placed on the control panel to cammand the relative digital input of the drive.